Operating Fluid Compatibility

The standard system is designed for use with a wide range of fluids; however, the O-ring
seals are Nitrile; use of solvents, fuel oils, brake fluids or other, similar aggressive fluids
can damage the seals. The table below details the two alternative versions of this
instrument, which offer increased compatibility with other fluids.
Rotate reservoir dust cover through ½ turn and fill reservoir approximately 3/4 full with
the appropriate fluid. Rotate dust cover back to cover reservoir.
To avoid damage to the instrument, the operator should check
the quality of the operating fluid during use. If the fluid
becomes discolored, cloudy or particles appear in the reservoir,
the system should be drained and flushed with clean fluid.

Safety Information

The following are general safety precautions that are not related to any specific
procedures and do not appear elsewhere in this publication. These are recommended
precautions that personnel must understand and apply during equipment operation and
maintenance to ensure safety and health and protection of property.

Compressed Liquid

Use of compressed liquids can create an environment of propelled foreign matter.
Pressure system safety precautions apply to all ranges of pressure. Care must be taken
during testing to ensure that all hydraulic connections are properly and tightly made prior
to applying pressure. Personnel must wear eye protection to prevent injury.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.

Personal Protective Equipment

Wear eye protection approved for the materials and tools being used.

Symbols Used in this Manual

In this manual, a Warning identifies conditions and actions that pose a hazard to the
user. A Caution identifies conditions and actions that may damage the Hydraulic
Comparison Test Pump.
Symbols used on the Hydraulic Comparison Test Pump and in this manual are explained
in Table 2.
2
Table 1. Operating Fluid Compatibility
Model
P5514
Nitrile
P5514-V
Viton
P5514-EP
Ethylene Propylene
W Caution
W Warning
O Rings

Advertisement

Table of Contents
loading

Table of Contents