OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Ni-Cd)
BATTERY PROTECTION
INDICATIONS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
ILLUMINATION SOURCE
ILLUMINATION (MAINS / EMERGENCY)
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
Thank you for purchasing this product of Olympia
Electronics. A European manufacturer.
GENERAL
These luminaires are used in places where
emergency luminaires are needed. Each luminaire
must be permanently connected to mains power
supply. In normal operation the led strip lights and
the battery is charging. In case of a mains power
supply failure the luminaire will light the led strip
automatically in emergency mode. When the mains
power
supply
is
normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions on page 2.
OPERATION
Battery Cut-off
The luminaire enters in this operation when the
mains power supply fails and battery has lost its
energy. During this operation the luminaire enters
the idle state and battery consumption is negligible,
in order to be protected from deep discharge.
Battery charging
The battery charging is completely controlled. In this
case, is achieved the perfect battery maintenance ,
as well as the elongation of its duration. When the
battery has completely charged, it charges with a
maintenance current.
Manual Test
The manual test can be conducted only if the main
power supply and the battery is connected. By
pressing the TEST/RESET button briefly (page 2)
an operation test is initiated. During this test period
all indication LEDs are OFF.
Automatic test
This test includes all the operations that provide the
manual test and is conducted automatically
Page 1 from 2
TECHNICAL CHARACTERISTICS
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
restored the device turns to
High Quality European based Manufacturers
220-240V AC/50-60Hz
4W/7VA
3.6V/3Ah
From overcharge and full discharge
Charge, lamp fault, fault indication LED
24h
480min
15 white LED's
105lm / 105lm
IP 65
0 to 40 C
Up to 95%
Bayblend FR3010, transparent polycarbonate
363 x 145 x 73 mm
945gr.
3 years (1 year for the battery)
every 15 days. In order to be performed, the main
power supply and the battery should be connected.
Automatic Autonomous Test
The Automatic Autonomous Test is conducted and
measures the luminaire`s back up operation. This
test is conducted automatically every six months. In
order to be performed, the main power supply and
the battery should be connected (the battery should
be charged). If the battery is not charged, the test is
postponed until the battery is completely charged. If
during
the
Automatic
luminaire's duration is lower than the named, then
the battery must be replaced.
Back Up Operation
The
autonomous
emergency mode is at least the one that is stated in
the technical characteristics. During emergency
mode, a LED strip test is also performed.
Resetting Errors
Push the TEST/RESET button for 5 seconds, to
extinguish all the indicated LED errors (page 2).
Then the luminaire enters regular operation mode.
Indication LED status
(with connected mains power supply).
Charge
On:
Good charge current.
Οff:
No battery (No charging current or
disconnected battery).
Lamp fault
Οn:
Off:
Fault
Οff:
Blink (With Charge LED ON): Autonomy or low
battery problem
(the battery must be replaced).
Blink (With Charge LED Off):
No charging current or disconnected battery.
o
Autonomous
duration
of
battery
faulty LED strip.
Good LED strip.
Battery OK.
923940000_09_008
Test
the
during

Advertisement

loading

Summary of Contents for olympia electronics GR-940/15L

  • Page 1 High Quality European based Manufacturers GR-940/15L WATERPROOF SELF-TESTING EMERGENCY LUMINAIRES TECHNICAL CHARACTERISTICS OPERATION VOLTAGE 220-240V AC/50-60Hz MAXIMUM POWER CONSUMPTION 4W/7VA BATTERY (Ni-Cd) 3.6V/3Ah From overcharge and full discharge BATTERY PROTECTION INDICATIONS Charge, lamp fault, fault indication LED CHARGING TIME 480min...
  • Page 2 ΑΤΤΕΝΤΙΟΝ!!! NOTE: LED= Light Emitting Diode 1. Operations for installation, maintainance or LABELING EXPLANATION: testing must be done by authorized personel only. X: Self contained 1: Maintained 2. The device must be connected to the mains A: Including test device power supply thru a fuse dependent by the total 480: 8 hour duration amount of the line’s power load.