DeDietrich LN1GBQ41-C140-45 User Manual

DeDietrich LN1GBQ41-C140-45 User Manual

Gas-fired heating condensing boilers
Table of Contents

Advertisement

Quick Links

en
ADVANCE
User Guide
control box equipped with a DIEMATIC Evolution
Gas-fired heating condensing boilers
LN1GBQ41 – C140 – 45
LN1GBQ62 – C140 – 65
LN1GBQ86 – C140 – 90
S U S T A I N A B L E C O M F O R T ®

Advertisement

Table of Contents
loading

Summary of Contents for DeDietrich LN1GBQ41-C140-45

  • Page 1 ADVANCE User Guide control box equipped with a DIEMATIC Evolution Gas-fired heating condensing boilers LN1GBQ41 – C140 – 45 LN1GBQ62 – C140 – 65 LN1GBQ86 – C140 – 90 S U S T A I N A B L E C O M F O R T ®...
  • Page 2 Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
  • Page 3: Table Of Contents

    Contents Contents Safety ................... . 5 General safety instructions .
  • Page 4 Contents Technical data ................25 Appendix .
  • Page 5: Safety

    1 Safety Safety General safety instructions Danger This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 6: Safety Instructions For The User

    1 Safety 1.1.2 Safety instructions for the user Danger If you smell gas: 1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches (doorbell, light, motor, lift, etc.). 2. Shut off the gas supply. 3.
  • Page 7 1 Safety Caution Power the appliance via a circuit that includes an omnipolar switch with contact opening distance of 3 mm or more. Caution Have the boiler and heating system drained by a qualified professional if the home is left empty for a long period of time and there is a chance of frost.
  • Page 8: Liabilities

    2 About this manual Liabilities 1.3.1 Manufacturer's liability Our products are manufactured in compliance with the requirements of the various Directives applicable. They are therefore delivered with the marking and any documents necessary. In the interests of the quality of our products, we strive constantly to improve them.
  • Page 9: Symbols Used On The Appliance

    3 Description of the product 2.1.2 Symbols used on the appliance Fig.1 1 Alternating current. 2 Protective earthing. 3 Before installing and commissioning the appliance, carefully read the instruction manuals provided. 4 Dispose of used products through an appropriate recovery and recycling structure.
  • Page 10: Control Panel Description

    3 Description of the product Control panel description 3.3.1 Control panel components Fig.3 Control panel components 1 Rotary knob to select a tile, menu or setting 2 Confirm button to confirm the selection 3 Back button Short button press: Return to the previous level or previous menu Long button press: Return to home screen 4 Menu button...
  • Page 11 3 Description of the product Meaning of the icons in the display Tab.2 Icons Icon Description User menu: user-level parameters can be configured. Installer menu: installer-level parameter can be configured. Information menu: read out various current values. System settings: system parameters can be configured. Error indicator.
  • Page 12: Operation

    4 Operation Operation General Commissioning the boiler is done for first time use, after a prolonged shut- down (more than 28 days) or after any event that would require complete re-installation of the boiler. Commissioning of the boiler allows the user to review the various settings and checks to be made to start up the boiler in complete safety.
  • Page 13: Frost Protection

    5 Settings Frost protection Caution Drain the boiler and central heating system if you are not going to use your home or the building for a long time and there is a chance of frost. The frost protection does not work if the boiler is out of operation.
  • Page 14: Activating Holiday Programs For All Zones

    5 Settings Tab.4 Selectable tiles for the user Tile Menu Function Information menu. Read out various current values. Error indicator. Read out details about the current error. With some errors the icon will appear with installer contact details (when filled in). Holiday mode.
  • Page 15: Changing The Room Temperature Of A Zone

    5 Settings Menu Function Programmes horaires pour le chauffage Set and configure the time programs used when in operating mode Programmation. Configuration de zone Configure the settings of the zone circuit. Tab.6 Extended menu to configure a heating circuit Configuration de zone Menu Function Dérogation de température...
  • Page 16: Changing The Operating Mode Of A Zone

    5 Settings Fig.9 Letter selection 7. Change the name of the zone (20 characters maximum): 7.1. Use the rotary knob to select a letter, number or action. 11:20 ....: ....7.2. Select to delete a letter, number or symbol. 7.3.
  • Page 17 5 Settings 8. Press the button to confirm the selection. Activities scheduled for Monday are displayed. The last scheduled activity of a day is active until the first activity of the next day. At initial start-up, all weekdays have two standard activities; Home starting at 6:00 and Sleep starting at 22:00.
  • Page 18: Changing The Heating Activity Temperatures

    5 Settings 8. Change the name of the activity: 8.1. Press the rotary knob to repeat a letter, number or symbol. 8.2. Select to delete a letter, number or symbol. 8.3. Select to add a space. 9. Select the sign on the screen when the name is complete. 10.
  • Page 19: Timer Program To Control The Dhw Temperature

    5 Settings 3. Use the rotary knob to select the desired operating mode: Tab.10 DHW operating modes Icon Mode Description Scheduling The domestic hot water temperature is controlled by a timer program Manual The domestic hot water temperature is set to a fixed setting Hot water boost The domestic hot water temperature is increased temporarily Holiday...
  • Page 20: Changing The Comfort And Reduced Hot Water Temperature

    5 Settings 5.6.3 Changing the comfort and reduced hot water temperature You can change the comfort and reduced hot water temperature in the timer program. 1. Select the tile [ 2. Select Zone configuration > Domestic Hot Water Setpoints. 3. Select the DHW setpoint you want to change: 3.1.
  • Page 21: Maintenance

    6 Maintenance 5. Perform one of the operations described in the table below: Tab.11 Display settings System Settings menu Settings Set Date and Time Set the current date and time Select Country and Language Select your country and language Daylight Saving Time Enable or disable daylight saving time Installer Details Read out the name and phone number of the installer...
  • Page 22: Refilling The Central Heating System

    6 Maintenance Refilling the central heating system Fig.14 Refilling the system If the central heating system is empty or the water pressure is too low, the central heating system must be (re)filled. To do this, proceed as follows: 1. Check the water pressure of the central heating system shown on the control panel display.
  • Page 23: Venting The Heating System

    6 Maintenance 15. Put the boiler back into operation after the central heating system has been filled and vented. Important Filling and venting the central heating system twice a year should be sufficient to maintain the correct water pressure. If it is often necessary to top up the central heating system with water, contact your fitter Venting the heating system...
  • Page 24: Draining The Heating System

    7 Troubleshooting Draining the heating system Fig.18 It may be necessary to drain the central heating system if radiators need to be replaced, if there is a major water leak or if there is a risk of freezing. 1. Open the valves on all the radiators connected to the system. 2.
  • Page 25: Display Of Error Codes

    8 Technical specifications Important The error code is needed to find the cause of the error quickly and correctly and for any support from De Dietrich. 7.1.1 Display of error codes Fig.20 Diematic Evolution When an error occurs in the installation, the control panel shows: The display will show a corresponding code and message.
  • Page 26 8 Technical specifications C140 C140 – 45 C140 – 65 C140 – 90 Part load heating mode efficiency (92/42/EEC) 110.6 110.4 108.1 (return temperature 30 °C) Part load heating mode efficiency (GB20665– 108.0 107.8 107.9 2015) (return temperature 30 °C) (1) Factory setting Tab.14 Gas and flue gas values...
  • Page 27: Appendix

    9 Appendix Tab.18 Other data C140 C140 – 45 C140 – 65 C140 – 90 Total weight (empty) Appliance dimensions 1340 x 600 x 1340 x 600 x 1562 x 600 x Height x Width x Depth Average acoustic level at a distance of one me­ dB(A) tre from the boiler The back cover for contact details.
  • Page 28: Package Fiche - Boilers

    9 Appendix Package fiche - Boilers Fig.21 Package fiche for boilers indicating the space heating energy efficiency of the package Seasonal space heating energy effi ciency of boiler ‘I’ Temperature control Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, from fi...
  • Page 29: Ec Declaration Of Conformity

    9 Appendix The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. The factor for weighting the heat output of preferential and supplementary heaters of a package as set out in the following table.
  • Page 30 9 Appendix DIEMATIC Evolution - C140 7745361 - v03 - 29112021...
  • Page 31 Original instructions - © Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.
  • Page 32 57, rue de la Gare - F-67580 Mertzwiller 03 88 80 27 00 SERVICE CONSOMMATEURS 0 825 120 520 0,15 / min 03 88 80 27 99 www.dedietrich-thermique.fr VAN MARCKE NV 000 «БДP T » LAR Blok Z, 5 129164, Россия, г. Москва B- 8511 KORTRIJK Зубарев...

This manual is also suitable for:

Ln1gbq62-c140-65Ln1gbq86-c140-90

Table of Contents