Page 2
These instructions should be used to aid installation of the following products: and current Building Regulations. If in any doubt, consult a qualified electrician AC65136EM / AC65158EM / AC651581EM / AC65170EM / AC65236EM / AC65258EM / AC652581EM / • Please isolate mains prior to installation or maintenance AC65270EM •...
Page 3
Fig. 1 • Remove the gear tray from the baseplate by pinching the clips at two locations (see Fig. 2) • Remove the gear tray from the baseplate by pinching the clips at two locations (see Fig. 2) Fig. 2 Fig.
Page 4
made Ensuring correct polarity is observed, carefully wire as shown in Fig. 4 • Fig. 4 Fig. 4 • Ensure the battery is connected via the plug and socket to the emergency inverter Ensure the battery is connected via the plug and socket to the emergency inverter •...
Page 5
If this product should fail within its warranty period, it should be returned to the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not...
Page 6
TESTING FOR EMERGENCY LUMINAIRES Recommended routine test procedure in accordance with BS5266 • Daily check – check LED charge indicator is illuminated • Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch or switching off circuit breaker.