Command
Function (Conexant)
+MS= a , b , c , d , e , f
Select modulation ( b , c , d , e , and f are optional).
a is the carrier (allowable rates in parentheses): B103 (300), B212 (1200 Rx/75 Tx or 75 Rx/1200 Tx),
V21 (300), V22 (1200), V22B (1200/2400), V23C (1200), V32 (4800/9600), V32B (4800–14400), V34
(2400–33600), K56 (32000–56000), V90 (28000–56000), V92 (downstream: 28000–56000; upstream:
24000–48000).
b is automode: 0=disabled, 1=enabled (default).
c is minimum transmit (Tx) rate (bps).
d is maximum transmit rate (bps).
e is minimum receive (Rx) rate.
f is maximum receive rate (bps).
+WS= n
Set PDC mode: 1=disable (default), 20=enable.
ECC Commands
%C n
Set data compression: 0=disable, 1=enable V.42 bis and MNP 5, 2=enable V.42 bis and MNP 5,
3=enable V.42 bis and MNP 5 (default).
+EB= a , b , c
Select break handling ( b and c are optional):
a =0 — break is ignored.
b =0 — transmitted V.42 L-SIGNAL will not indicate break signal length.
c =0 — break is not delivered to DTE.
+EFCS=0
Select 16-bit FCS specified in V.42.
+ER: a
Select error control protocol: NONE=error control not in use, LAPM=V.42 LAPM protocol, ALT=MNP.
+ER= n
Error control reporting: 0=disable, 1=enable.
+ES= a , b , c
Select error control and synchronous mode ( b and c are optional).
a is requested mode when modem is originator: 0=initiate call with direct mode, 1=initiate call with
normal mode, 2=initiate V.42 without detection phase, 3=initiate V.42 with detection phase (default),
4=initiate MNP, 6=initiate V.80 synchronous access mode when connection is completed.
b specifies fallback mode when modem is originator: 0=LAPM, MNP, or normal mode error control
optional (default); 1=LAPM, MNP, or direct mode error control optional; 2=LAPM or MNP error control
required; 3=LAPM error control required; 4=MNP error control required.
c specifies fallback mode when modem is answerer or specifies V.80 synchronous access mode:
1=error control disabled, use normal mode; 2=LAPM, MNP, or normal mode error control optional
(default); 3=LAPM, MNP, or direct mode error control optional; 4=LAPM or MNP error control
required; 5=LAPM error control required; 6=MNP error control required; 8=initiate V.80 synchronous
access mode when connection complete.
+ESR=0
Disable selective repeat option in V.42.
+ETBM= a , b , c
Handle data remaining in modem buffers on call termination ( b and c are optional):
a =0 — disconnect occurs immediately and buffered transmit data is discarded.
b =0 — disconnect occurs immediately and buffered receive data is discarded.
c =0 — modem does not attempt to deliver buffered data and discards data.
FAX Class 1
+FAE= n
Data/fax auto answer: 0=disable (default), 1=enable.
+FAR= n
0=disable adaptive reception (default), 1=enable.
+FCL= n
Set loss-of-carrier delay in units of 100 ms ( n =0 to 255).
+FCLASS= n
Set active service class: 0=data mode (default), 1=Fax Class 1, 1.0=Fax Class 1.0 mode, 8=voice
mode.
+FIT= n , a
Set DTE inactivity timeout n seconds after which modem goes on-hook ( a =0) or DCE goes on hook
( a =1).
+FLO= a
Set flow control type: 0=XON/XOFF and RTS/CTS flow control turned off; 1=XON/XOFF flow control
in either direction; 2=RTS for flow control of modem by DTE, and CTS for flow control of DTE by
modem.
Reference Information
Modem Reference Information
Corporate Evaluator's Guide
169