Download Print this page

Friedrich Hazardgard SH20M50B Installation & Operation Manual page 20

Hazardous location room air conditioner

Advertisement

Available languages

Available languages

Figure 25
SECTION A -A
TOP OF CABINET
WINDOW JAM
PLACE WINGBOARD PANEL IN
WINDOW JAM TO COMPRESS THE
SPRINGS INSIDE THE RUNNERS,
AND SWING THE PANEL INTO PLACE
INDICATED BY THE DOTTED LINE.
STEP 6 INSTALL SIDE WINGBOARD PANELS: Be sure that the cabinet has been secured to the window sill and the outside support
brackets have been installed as shown in (Figures 19 and 20) on Page 17. Raise the window sash and install the right and left
side wingboard panels (See Figure 25).
STEP 7 INSTALL WINDOW SEALING GASKETS: Measure and cut the dark foam window seal gasket (Item#12) and install it between
the upper glass panel and the top part of the lower sash (Figure 26).
Figure 26
NOTE
FOR REASONS OF SECURITY , THE CUSTOMER MUST PROVIDE A MEANS OF PREVENTING THE WINDOW FROM OPENING.
STEP 8 When possible, caulk the outside of the installation with industrial type caulking to prevent air and water leaks.
STEP 9 Skip to chassis wiring and preparation on page 21 for Non ATEX or page 23 for ATEX and IECEx.
CLIP (ITEM10)
20