Maytag Amana GMES9 Series Service Instructions Manual page 9

Single stage gas furnaces and accessories
Table of Contents

Advertisement

PRODUCT IDENTIFICATION
MODEL #
GMES920403ANAA
GMES920603BNAA
GMES920803BNAA
GMES920804CNAA
GMES92
GMES920805CNAA
GMES921004CNAA
GMES921005CNAA
GMES921205DNAA
GMES960403ANAA
GMES960603BNAA
GMES960803BNAA
GMES96
GMES960804CNAA
GMES960805CNAA
GMES961005CNAA
GMES961205DNAA
GCES960403BNAA
GCES960603BNAA
GCES96
GCES960804CNAA
GCES961005CNAA
GCES961205DNAA
VMES960403ANAA
VMES960603BNAA
VMES96
VMES960803BNAA
VMES960804CNAA
VMES961005CNAA
VCES960403BNAA
VCES960603BNAA
VCES96
VCES960804CNAA
VCES961005CNAA
MFG #
Goodman® Brand 92% Single Stage Gas Furnace. 34.5" tall, Upflow/Horizontal
Installation, 1-stage gas valve induced draft. PSC motor. 120-volt silicon carbide
17-second hot surface ignition. Left or right gas pipe entry. The furnace also
features an aluminized steel tubular heat exchanger. Available cabinet widths are
14", 17.5", 21", and 24.5" wide. Minor Revision B has a Nidec motor for increased
CFMs.
Goodman® Brand 96% Single Stage Gas Furnace. 34.5" tall, Upflow/Horizontal
Installation,1-stage gas valve induced draft. PSC motor. 120 volt silicon carbide
17-second hot surface ignition. Left or right gas pipe entry. The furnace also
features an alumininized steel tubular heat exchanger. Available cabinet widths
are 14", 17.5" ,21" and 24.5" wide. Minor revision B has a Nidec motor for
increased CFMs.
Goodman® Brand 96% Single Stage Gas Furnace. 34.5" tall,
Downflow/Horizontal Installation, 1-stage gas valve induced draft. PSC motor.
120-volt silicon carbide 17-second hot surface ignition. Left or right gas pipe
entry. The furnace also features an aluminized steel tubular heat exchanger.
Available cabinet widths are 17.5", 21" and 24.5 " wide.
GMC® Brand 96% Single Stage Gas Furnace. 34.5" tall, Upflow/Horizontal
Installation, 1-stage gas valve induced draft. PSC motor. 120-volt silicon carbide
17-second hot surface ignition. Left or right gas pipe entry. The furnace also
features an aluminized steel tubular heat exchanger. Available cabinet widths are
17.5", and 21" wide.
GMC® Brand 96% Single Stage Gas Furnace. 34.5" tall, Downflow/Horizontal
Installation, 1-stage gas valve induced draft. PSC motor. 120-volt silicon carbide
17-second hot surface ignition. Left or right gas pipe entry. The furnace also
features an aluminized steel tubular heat exchanger. Available cabinet widths are
17.5", and 21" wide.
DESCRIPTION
9

Advertisement

Table of Contents
loading

Table of Contents