PRODUCT IDENTIFICATION
MODEL #
AFE18-60A
AMU1620
AMU1625
AMU2020
AMU2025
GMU1620
GMU1625
GMU2020
GMU2025
ASAS-10
ASAS-11
ASAS-12
ASAS-18
CFSB17
CFSB21
CFSB24
MFG #
Fossil Fuel Kit. The AFE18-60A control is designed for use where the indoor coil is
located above/downstream of a gas or fossil fuel furnace when used with a heat pump.
It will operate with single and two stage heat pumps and single and two stage
N/A
furnaces. The AFE18-60A control will turn the heat pump unit off when the furnace is
turned on. An anti-short cycle feature initiates a 3 minute timed off delay when the
compressor goes off.
P1251305F
P1251306F
Media Air Cleaner. A high efficiency air filtration device designed to remove dirt, dust,
P1251307F
pollen and other microscopic particles from the air passing through it. Flexible
P1251308F
performance range up to 2,000 CFM capacity. The air cleaner should be installed in the
system so that all the system air is circulated through the air cleaner. The air cleaner
will only remove the airborne contaminants delivered to it. Maximum performance is
obtained when the system blower is set for continuous operation. Carbon filters
N/A
(optional) are available.
Electronic Air Cleaner. The High-Efficiency Electronic Air Cleaner is designed to
P1251301F
remove air contaminants down to .01 microns. Carbon filters (optional) remove odors.
P1251302F
Dual indicator lights show unit operation at a glance. Electronic proving switch cycles
P1251303F
the air cleaner On/Off with the system fan. Durable powder-coat paint finish resists
P1251304F
corrosion.
Counterflow Subbase Kit. For use with 34.5" down flow furnace models. These kits
are available for the following furnace widths: 17.5" wide (CFSB17), 21" wide (CFSB21)
and 24.5" wide (CFSB24). The kits must be used to prevent excessive temperature
N/A
from reaching combustible materials, if the furnace is installed on a combustible floor.
This subbase effectively separated the furnace base and plenum from combustible
materials. To ensure safe installation, do not install the counterflow floor base directly
on carpeting, tile, or other combustible material other than wood flooring.
DESCRIPTION