TROUBLE
1. Fan will not
start.
2. Fan sounds
noisy.
3. Fan wobbles
excessively.
Trouble Shooting
PROBABLE CAUSE
1. Fuse or circuit breaker
blown.
2. Loose power line
connections to the fan, or
loose wire connections in
the switch housing.
3. Remote control switch is off.
4. Defective battery in remote
control transmitter.
5. Code switches in remote
control receiver and transmitter
are not set in the same position.
1. Blades not attached to fan.
2. Screws securing fan blade
flanges to motor are loose.
3. Wire connectors inside switch
housing rattling.
4. Screws holding blades to
flanges are loose.
5. Loose screws in motor housing. 5. Check to make sure all screws
1. Setscrew in motor coupling is
not tightened securely.
2. Setscrew in the hanger ball/
downrod assembly is loose.
3. Screws securing fan blade
flanges to motor are loose.
4. Fan blade flanges not seated
properly.
5. Hanger bracket and/or ceiling
outlet box is not securely
fastened.
6. Fan blades out of balance.
SUGGESTED REMEDY
1. Check main and branch
circuit fuses or circuit breakers.
2. Check line power connections
to fan and wire.
3. Turn on remote control .
4. Check that the battery is good
(red indicator light should
illuminate when any button is
pressed).
5. Check that both code switches
are set in the same positions.
WARNING: Make sure
!
main power is turned off.
1. Attach blades to fan before
operating.
2. Check to make sure the screws
which attach the blade flanges
to the motor are tight.
3. Check to make sure wire
connectors in switch housing
are not rattling against each
other or against the interior wall
of the switch housing.
WARNING: Make sure main
!
power is turned off.
4. Tighten screws securely.
in motor housing are snug
(not over-tight)
1. Raise coupling cover and tighten
setscrew securely.
2. Tighten the setscrew in the
hanger ball/downrod assembly.
3. Check to be sure screws which
attach the fan blade flanges
to the motor are tight.
4. Check to be sure that the
screws securing the fan
blade flanges seat firmly.
5. Tighten the hanger bracket
screws to the outlet box, and/or
secure outlet box.
6. Interchanging an adjacent (side
by-side) blade pair can
redistribute the weight and result
in smoother operation.
Or use supplied balancing kit to
balance blades.
16