Danfoss VLT HVAC Drive FC100 Service Manual page 16

High power f frames
Table of Contents

Advertisement

Introduction
Mains Supply 3 x 525- 690V AC
Typical Shaft output at 550 V [kW]
Typical Shaft output at 575 V [HP]
Typical Shaft output at 690 V [kW]
Enclosure IP21, 54 without/ with options
cabinet
Output current
Continuous
(at 550 V) [A]
Intermittent (60 sec overload)
(at 550 V) [A]
Continuous
(at 575/ 690 V) [A]
Intermittent (60 sec overload)
(at 575/ 690 V) [A]
Continuous KVA
(at 550 V) [KVA]
Continuous KVA
(at 690 V) [KVA]
Max. input current
Continuous
(at 550 V ) [A]
Continuous
(at 575 V) [A]
Continuous
(at 690 V) [A]
2
2)
Max. cable size, motor [mm
(AWG
)]
2
Max. cable size,mains F12 [mm
(AWG
2
Max. cable size,mains F13 [mm
(AWG
2
2)
Max. cable size, brake [mm
(AWG
)
Max. external mains fuses [A]
1
Estimated power loss
at 600 V [W]
4)
Estimated power loss
4)
at 690V [W]
F3/F4 Max added losses CB or Disconnect &
Contactor
Max panel options losses
Weight,
enclosure IP21, IP 54 [kg]
Weight, Rectifier Module [kg]
Weight, Inverter Module [kg]
4)
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
* High overload = 160% torque during 60 sec., Normal overload = 110% torque during 60 sec.
1) For type of fuse see section Fuses.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to
variety in voltage and cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line).frequency converter
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to
30W to the losses. (Though typical only 4W extra for a fully loaded control card, or options for slot A or slot B,
each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be
allowed for (+/-5%).
High Power Service Manual for Modular F Frame Drives
P1M0
850
1150
1000
F12/F13
1108
1219
1060
1166
1056
1267
1079
1032
1032
2)
)]
2)
)]
1600
15592
16375
665
1246/ 1541
136
102
®
MG90K202 - VLT
is a registered Danfoss trademark
P1M2
1000
1350
1200
F12/F13
1317
1449
1260
1386
1255
1506
1282
1227
1227
12x150
(12x300 mcm)
8x240
(8x500 mcm)
8x400
(8x900 mcm)
6x185
(6x350 mcm)
2000
18281
19207
863
400
1246/ 1541
136
102
0.98
0-500 Hz
85 °C
68 °C
1
P1M4
1100
1550
1400
F12/F13
1479
1627
1415
1557
1409
1691
1440
1378
1378
2500
20825
21857
1044
1280/1575
136
136
15
1