Output Load Connection

The Power Supply provides two sets of 12VDC output terminals, V1+ and V2+.
Both V1+ and V2+ outputs are individually fused, with 6 terminals associated to each output and its individual
fuse.
A maximum current output of 6.0 Amps at 12VDC can be provided across each output at any one time.
However, if a single current output of 8.0 Amps is required, then both outputs need to be connected together in
parallel.
When any inductive load including electric locking devices is powered (directly or indirectly) by the Power
Supply, a reverse EMF protection diode must be placed across the positive (V1+ or V2+) and negative (V-)
terminals at the device.
Note: The 1N4007 diode shown MUST be installed across the + and – terminals of any inductive load such as
electric locks, magnetic or motorized devices.
PRT-PSU-DIN-8A | Protege DIN Rail 8A Intelligent Power Supply | Installation Manual
12VDC Electric
Locking Device
V1+ V1+ V1+ V1+ V1+
V1+
-
IN4007 Diode
V-
V-
V-
V-
V-
V-