Bosch Rexroth AG
Interfaces
Not all USB devices are detected.
The operating system does not support all USB devices. Devices that
require a special USB driver, which is not integrated in the system,
cannot be operated at the USB interfaces.
9.4 Ethernet interfaces X7E1, X7E2 and XETH1
Plug type
Cable length
Number
Maximum data transfer rate
Plug name
Tab. 9-2: Ethernet network interface
Ethernet interface — Status and diagnostic displays
LED Link
On: Connection to network available
●
Off: No connection
●
Flashing: Communication is running
●
LED Status
On: Communication is running
●
Off: No communication
●
LED Speed
Off: 10 MB
●
Green: 100 MB
●
Yellow: 1 GB
●
9.5 24 V DC voltage supply X1S
Cables up to a max. conductor cross-section of 1.5 mm
the connection terminal (pin strip SL grid 3.5 mm).
Fig. 9-3: 5-pin connection terminal for VEP xx.5 devices
14/41
Embedded Terminals with Profibus DP
Basic
RJ45, socket, 8-pin
100 m max.
1
10/100 MBit and 1 GBit
XETH1
X1S
1 2 3
4
Advanced
RJ45, socket, 8-pin
100 m max.
2
10/100 MBit and 1 GBit
X7E1, X7E2
2
can be connected to
5
DOK-CONTRL -VEP*XX.5***-IT01-EN-P
Master