Service Connections - Crown ECX-10 Installation & Operation Manual

Electric cabinet base convection steamer
Hide thumbs Also See for ECX-10:
Table of Contents

Advertisement

Service Connections

Service Connections
– ELECTRICAL CONNECTION: Field wiring electrical connection to be as specified on data plate.
– BOILER FEED WATER: 1/2" (13 mm) NPT at 25-50 PSI (170-345 kPa).
– CONDENSATE COLD WATER: 1/2" (13 mm) NPT at 25-50 PSI (170-345 kPa) (OPTIONAL)
– STEAM TAKE-OFF CONNECTION: 3/4" (19 mm) IPS optional to operate adjacent equipment.
– DRAIN: 2" (51 mm) IPS piped to open floor drain. No solid connection.
Available kW
Model
Standard
ECX-2-[24,36]
24
ECX-10-[24,36]
36
Model
Standard Boiler
ECX-2-[24,36]
24 kW
ECX-10-[24,36]
36 kW
Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a
Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for
warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.
Total dissolved solids..............Less than 60 PPM
Total alkalinity ....................... Less than 20 PPM
Water which does not meet these standards should be treated with the installation of Middleby's Water Treatment System. Call 919-762-1000 if you have
questions concerning your water meeting these parameters.
*Failure or malfunction of this appliance due to poor water quality is not covered under warranty.
Reference www.crownsteamgroup.com for complete warranty details and instructions.
Terry System Cartridge Changes / Installation – "2-3 gallons of water MUST be purged at each cartridge change or new installation prior to
water supply being fed to the steamer. Failure to do so can result in component damage within the steamer which is not covered under warranty.
For additional guidance on proper installation, refer to install documentation provided with each Terry System and Replacement Cartridge Set."
As continued product improvement is a policy of Crown, specifications are subject to changge without notice.
4
PAGE
OF 20
SERVICE CONNECTIONS
ELECTRICAL CHARACTERISTICS
kW
Phase
Optional
24
36, 42, 48
36
42, 48
42
48
COMPARTMENT PAN CAPACITY, WEIGHT AND CLEARANCE
Pan Depth
1"
2-1/2"
4"
6"
6
3
2
1
10
5
3
2
WATER QUALITY STATEMENT
INSTALLATION & OPERATION MANUAL 10058 REV 5 (09/21)
Electric Cabinet Base Convection Steamer
Amps Per Line
208V
220V
3
66.6
63.0
3
99.9
94.5
3
116.6
110.2
3
N/A
N/A
Shipping Weight
Model
(24" Cabinet)
ECX-2-[24,36]
550 lbs. [249 kg]
ECX-10-[24,36]
575 lbs. [260 kg]
Silica ............... Less than 13 PPM
Chlorine .......... Less than 1.5 PPM
DISCLAIMER
240V
380V
415V
57.8
36.5
33.4
86.6
54.7
50.1
101.0
63.8
58.4
115.5
72.9
66.8
Shipping Weight
Minimum Clearance
(36" Cabinet)
SIDES
650 lbs. [255 kg]
BACK
700 lbs. [317 kg]
pH Factor ......... 6.8 - 7.3