Download Print this page

Service Connections - Crown GSX-7HE Installation & Operation Manual

Gas fired steamers

Advertisement

S
C
ERVICE
ONNECTIONS
S
ERVICE
GSX-7HE & GSX-16HE
– ELECTRICAL CONNECTION: Unless otherwise specified, Electrical Connection to be 120 Volts, 6.
Hertz single phase with ground Furnished with 6 foot cord with 3 prong plug. Maxximum 4.0 amps.
– DRAIN: 2" (51 mm) IPS piped to open floor drain. No solid connection.
– GAS CONNECTION: 3/4" IPS supply line required.
– CONDENSATE COLD WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kPa)
– BOILER FEED WATER: 3/8" O.D. tubingat 25-50 PSI (170-345 kPa).
M
odel
GSX-7HE
GSX-10HE
GSX-16HE
Model
GSX-7HE
GSX-10HE
GSX-16HE
Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a
Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for
warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.
Total dissolved solids
Total alkalinity
Silica ..................................... Less than 13 PPM
Water which does not meet these standards should be treated with the installation of Middleby's Water Treatment System. Call 919-762-1000 if you have
questions concerning your water meeting these parameters.
*Failure or malfunction of this appliance due to poor water quality is not covered under warranty.
Reference www.crownsteamgroup.com for complete warranty details and instructions.
PAGE
4
OF 20
C
ONNECTIONS

SERVICE CONNECTIONS

GAS CHARACTERISTICS
BTu/Hr.
W/Hr.
k
140,000
41
190,000
56
190,000
56
Compartments
Capacity
2
1-7 Pans (2-1/2")
2
1-10 Pans (2-1/2")
2
1-16 Pans (2-1/2")
WATER QUALITY STATEMENT
Less than 60 PPM
Less than 20 PPM
INSTALLATION & OPERATION MANUAL 10124 REV 0 (03/21)
GSX-10HE
G
as
N
aTural
6"-14" (152-356mm)
6"-14" (152-356mm)
6"-14" (152-356mm)
SPECIFICATIONS
s
WT
HippiNG
650lbs (295kg)
700lbs (318kg)
900lbs (408kg)
Chlorine ......................... Less than 1.5 PPM
pH Factor ....................... 6.8 - 7.3
Gas Fired Steamers
s
p
upply
ressure
p
ropaNe
12"-14" (305-356mm)
12"-14" (305-356mm)
12"-14" (305-356mm)
C
learaNCe
SIDES
0
BACK
6 [152]