Contact the factory, the factory representative or a local service company to perform maintenance and repairs should
the appliance malfunction. Refer to warranty terms.
Disconnect the unit from the power supply before cleaning or servicing appliance.
Protect yourself. When flushing control, hot water and steam will flow out of the drain.
Be sure to flush your boiler water level control daily. Failure to follow this procedure can cause the control to malfunction
resulting in serious boiler damage.
The Boiler Water Level Control installed on your boiler requires periodic maintenance. As boiler water circulates into
the float chamber, sand, scale and other sediment may be deposited in the float chamber. While the chamber has been
designed with a large accumulation bowl, it is necessary to flush the sediment from the chamber by blowing down the
control so that the accumulation of sediment does not interfere with the movement of the float in the control.
Control must be flushed at least once a day.
10
PAGE
OF 20
M
AINTENANCE
Never spray water into electric controls.