Troubleshooting - Crown ECX-10 Installation & Operation Manual

Electric cabinet base convection steamer
Hide thumbs Also See for ECX-10:
Table of Contents

Advertisement

Troubleshooting

Electric Cabinet Base Convection Steamer
Troubleshooting
Door Leaks
1. Check for damage to door gasket.
Water Accumulates in the Compartment
1. Compartment drain screen clogged. Remove and clean thoroughly and replace.
Water Not Being Supplied to Boiler
1. Water supply is "OFF".
2. Defective water fill solenoid valve.
3. Water level control clogged or defective, unable to operate fill valve.
4. Check drain valve is closed. Also check that water level control valve is closed.
5. Supply water pressure too low.
Automatic Blowdown Valve Does Not Drain
1. Defective blowdown valve.
2. Heat exchanger build up of scalant clogging drain lines and valve.
Boiler Achieves Pressure Slower than Normal
1. Heavy build up of lime on elements.
2. Loose element connections.
Safety Valve Blows
1. Defective safety valve.
2. Pressure too high. Pressure switch requires adjustment (lower) or may be defective.
14
PAGE
OF 20
INSTALLATION & OPERATION MANUAL 10058 REV 5 (09/21)