Electric Cabinet Base Convection Steamer

Introduction

Description
Models ECX-2 and ECX-10 convection steamers mounted on cabinet base electric boiler. ECX-2 steamer has a pan
capacity of 6 (2-1/2") pans. ECX-10 steamer has a pan capacity of 10 (2-1/2") pans.
Installation Instructions
Unpacking
Immediately after unpacking, check for possible shipping damage. If the appliance is found to be damaged, save the
packaging material and contact the carrier within 15 days of delivery.
We cannot assume responsibility for damage or loss incurred in transit.
Location
Position the appliance in its installation location. Check that there are sufficient clerarances to service the controls, door
swing, etc. Also adequate clearance must be left for making the required supply and drain connections.
Allow enough space between any other piece of equipment or a wall for service access.
Service on the cabinet base may require access to the left and/or right side panels.
Leveling and Anchoring the Appliance
1. Place appliance in the installation position.
2. Place a carpenter's level on top of the appliance and turn the adjustable feet to level side-to-side and front-to-back.
3. Mark hole locations on the floor through the anchoring holes provided in the rear flanged adjustable feet.
4. Remove appliance from installation position and drill holes in locations marked on the floor. (See installation diagram
on page 4.) Insert proper anchoring devices (not supplied).
5. Place appliance back in the installation position.
6. Place carpenter's level on top of appliance and re-level side-to-side and front-to-back.
7. Bolt and anchor appliance securely to the floor.
8. Seal bolts and flanged feet with silastic or equivalent compound.
Installation Codes and Standards
The appliance must be installed in accordance with:
In Canada:
Provincial and local codes, or in the absence of local codes, with the Canadian Electric Code, CSA C22.1 (latest edition).
Copies may be obtained from the Canadian Standards Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada, M9W 1R3.
In the USA:
State and local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA-70 (latest edition). Copies
may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA, USA, 02269.
INSTALLATION & OPERATION MANUAL 10058 REV 5 (09/21)
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
I
NSTALLATION
5
PAGE
OF 20