GAS CABINET BASE CONVECTION STEAMER, GCX-16, GCX-24

10.0 TROUBLESHOOTING

NOTICE: Contact the factory, the factory representative or local
service company to perform maintenance and repairs. Refer to
warranty terms.
NOTICE: At least twice a year have an authorized service person
clean and adjust the unit for maximum performance.
DOOR LEAKS
1. Check for damage to door gasket.
2. Compartment drain opening or associated piping may be blocked.
WATER ACCUMULATES IN THE COMPARTMENT
1. Compartment drain screen clogged. Remove and clean thoroughly and replace.
SAFETY VALVE BLOWS
1. Defective safety valve.
2. Pressure too high. Pressure switch requires adjustment (lower) or may be defective.
WATER NOT BEING SUPPLIED TO BOILER
1. Water supply is "OFF".
2. Defective water fill solenoid valve.
3. Water level control clogged or defective, unable to operate fill valve.
4. Check drain valve is closed. Also check that water level control valve is closed.
5. Supply water pressure too low.
MANUAL 10064R2