Download Print this page

Lamona NBT625/2NX Instruction Manual page 11

Advertisement

CARBON FILTER
Activated carbon filter can be used to trap odors. Normally the activated carbon filter
should be changed at three or six months according to your cooking habit. The
installation procedure of activated carbon filter is as below.
(1) Slide the front part of the cooker hood.
(2) The al filter should be detached first. Press the lock and pull it downward.
(3) Take out the carbon filter by rotating the carbon filter anti-clockwise.
(4) Replace the new carbon filter.
NOTE:
 Make sure the filter is securely locked. Otherwise, it would loosen and cause
dangerous.
 When activated carbon filter attached, the suction power will be lowered.
BULB REPLACEMENT
Important :
(1) Switch off the appliance and unplug it.
(2) Slide the front part of the cooker hood.
(3) The al filter should be detached first. Press the lock and pull it downward.
(4) Replace with same type of light.230V~50Hz, MAX.2.5W LED
ILCOS D code for this lamp is: DBS-2.5/65-H-120/33.
– Max wattage: 2.5W
– Voltage range: AC 230V
– Dimensions:
 The bulb must be replaced by the manufacturer, its
service agent or similarly qualified persons.
 Always switch off the electricity supply before
carrying out any operations on the appliance. When
handling bulb, make sure it is completely cool down
before any direct contact to hands.
 When handling globes hold with a cloth or gloves to
ensure perspiration does not come in contact with
the globe as this can reduce the life of the globe.
 
11

Advertisement

loading