Tcp/Ip Web Based Utility Option - ICT Sine Wave ICT1500-12W Instruction Manual

Table of Contents

Advertisement

Vac-Low
Vac-High
Transfer
Transfer
94 (204)
114 (230)
99 (212)
120 (240)
Table 3: AC Transfer Switch Threshold Setting
The 15A (7A on 230V models) circuit breaker located on the back panel is a
supplementary overcurrent protection device, to limit potential fault currents
when operating from an external AC source. If this breaker trips it is indicating
that your connected load is drawing excessive current from the unit, or that
there is a fault with the AC wiring.
Note that disabling the inverter output on units with the transfer relay option
will not cut power to the load if AC is being supplied by an external source via the
internal transfer relay.

TCP/IP WEB BASED UTILITY OPTION

Connecting the inverter to the Internet using the optional TCP/IP communication
port (Option "C") enables full remote monitoring and control of the inverter via
the on-board graphical web interface using any standard web browser, such
Microsoft Explorer, Google Chrome, or Mozilla Firefox.
To connect with your networked inverter, do the following:
Start your browser
Enter the IP address of the inverter in the address field of your browser
as shown:
If the inverter is connected to a network with a DHCP server it will be assigned an
IP address automatically. To find the current IP address of the inverter you will
need to run the IP Address Discovery Utility (available on the Tools download
section of the ICT Web page
locate the connected inverter and see the assigned IP address. Run the utility on
a Windows computer connected to the same network as the inverter, and it will
report the IP addresses of all ICT units connected to that network.
The inverter will otherwise use the factory default IP address of 192.168.0.180,
as shown above.
Enter your username and password once you are connected to the unit.
The default Administrator user name is admin, with no password.
All manuals and user guides at all-guides.com
Switch settings (1 = "on", or down)
SW-1
0
1
http://www.ictcorporate.com/resources/tools/
Innovative Circuit Technology Ltd.
SW-2
SW-3
1
1
1
1
SW-4
1
1
) to