  • Page 1 Innovative Circuit Technology Ltd. ICT SITE INVERTER 300 INSTRUCTION MANUAL 855-131-002 Rev. B ICT300-12SNV ICT300-24SNV ICT300-48SNV...
  • Page 2 Do not attempt to operate the inverter from any power source other than a battery. The 12V inverter (ICT300-12SNV) must be connected to a 12V battery. The 24V inverter (ICT300-24SNV) must be connected to a 24V battery. The 48V inverter (ICT300-48SNV) must be connected to a 48V battery.
  • Page 3 Up to three ICT SITE INVERTER 300 units can be mounted in a single 1RU 19-inch rack shelf to provide almost 1kW of power (non-parallel) and six AC outlets in an ultra-compact, space saving design.
  • Page 4 Figure 1. ICT SITE INVERTER 300 Front Panel Figure 2. ICT SITE INVERTER 300 Rear Panel PROTECTIONS Overload Protection The inverter will shut down if the AC output is shorted or if the continuous draw exceeds 300 Watts for more than three seconds. The inverter can be manually reset by turning the power switch located on the front panel off then on.
  • Page 5: Installation

    If installing the ICT SITE INVERTER 300 into an equipment rack, use the optional 1RU 19- inch rack mounting kit (part number ICT-RM1U). 1, 2 or 3 inverters can be installed in one ICT-RM1U. Position the inverter into the rack tray, and using the supplied #6-32 x 3/16” flat head Phillips mounting screws, fasten the inverter to the tray by inserting the screws through the tray and into the integrated nuts located on the bottom of the inverter.
  • Page 6: Operation

    Figure 4. ICT SITE INVERTER 300 Rack Mount Installation WIRE SIZING GUIDE 12V Inverter 24V Inverter 48V Inverter Distance of Recommended Recommended Recommended Inverter from Input Wire Size Input Wire Size Input Wire Size Battery (copper) (copper) (copper) 10AWG 12AWG 12AWG 0 –...
  • Page 7: Troubleshooting

    48V inverter). • The inverter may have overheated. The inverter will automatically restart after it cools down. Ensure that the unit has adequate ventilation if this happens. PRODUCT SPECIFICATIONS ICT300-12SNV ICT300-24SNV ICT300-48SNV Input Voltage 10.5 – 16.0VDC 21.0 – 32.0VDC 42.0 –...
  • Page 8 The Purchaser shall at their own risk and cost return the defective product to ICT’s factory or designated repair center once an RMA is issued by ICT. Return of the products to the customer after repair is completed shall be prepaid by ICT unless otherwise mutually agreed between the parties.