Konica Minolta PF-124 Service Manual page 19

Table of Contents

Advertisement

15. Perform another test print and check the reference deviation.
16. Repeat the adjustment until the reference line falls within the specified range.
17. After making the adjustment, tighten the three screws that were loosened at step 15.
13. Slide out the Drawer and remove the paper.
14. Loosen three screws.
4348U008AB
• If width A is wider than the specified range:
Move the Trail Edge Stop toward the front.
• If width A is narrower than the specified range:
Move the Trail Edge Stop toward the rear.
4348U009AA
D-9

Advertisement

Table of Contents
loading

Table of Contents