8.1 Ethernet connection – no router
Follow the steps detailed below to enable control of your C550c system directly from your WinCan VX
enabled PC, without a router.
1 Connect an Ethernet cable between the Ethernet port on the flexitrax C550c controller and an
Ethernet socket on the PC.
2 From the C550c controller Start-up screen, select
Settings > Network > Ethernet settings
3 Set the IP assignment to Manual.
4 Set the IP address to 192.168.1.35
Note: You can choose an arbitrary IP address, but it must be of this format. If you select a different IP
address, ensure the next steps follow a similar layout.
5 Set the Subnet mask to 255.255.255.0
6 Set the Default gateway to 192.168.1.
7 Set the DNS server to 192.168.1.1
8 Select Save & Exit to return to Network settings
9 Confirm that the Ethernet IP matches your selected IP address
C550c Operation Manual