The NI TB-2627 is rated for 300 V, Measurement Category I. Do not use this module with the NI PXI/PXIe-2527 for connections to signals or for measurements within Categories II, III, or IV. Do not connect to MAINs supply circuits (for example, wall outlets) of 115 or 230 VAC.
Conventions The following conventions are used in this guide: » The » symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box.
Store the terminal block in the antistatic package when not in use. 2. Verify the Components Make sure you have the following: ❑ NI TB-2627 terminal block ❑ NI PXI/PXIe-2527 switch module ❑ PXI chassis ❑ 1/8 in. flathead screwdriver ❑...
Page 5
10. Replace the terminal block top cover. 11. Secure the terminal block top cover with the top cover screw. COM1– COM1+ Connect pin 1 COM0– COM0+ Connect 1 Terminal Block Top Cover 6 Strain-Relief Opening 2 Top Cover Screw 7 Strain-Relief Bar 3 Safety Ground Lug 8 Screw Terminals 4 Chassis Screws...
4. Install the Terminal Block To connect the NI TB-2627 terminal block to the NI PXI/PXIe-2527 front panel, complete the following steps: Note The NI PXI/PXIe-2527 should already be installed in a PXI chassis. Plug the NI TB-2627 into the front connector of the NI PXI/PXIe-2527.
HV6-BAN4 DMM cable National Instruments 192795-0R2 Specifications This section lists additional specifications for the NI TB-2627 used with the NI PXI/PXIe-2527. All specifications are subject to change without notice. Visit for the most current specifications. ni.com/manuals Input Characteristics All input characteristics are DC, AC , or a combination unless otherwise specified.
Page 15
LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National...
Page 16
取り付け手順 NI TB-2627 NI PXI/PXIe-2527 用端子台 NI TB-2627 このガイドでは、 端子台の取り付けおよび信号の接続方法、 NI PXI/PXIe-2527 および スイッチモジュールを次のいずれかに構成する 方法を説明します。 • × 単線式 マルチプレクサ • × 線式 マルチプレクサ • × 線式 マルチプレクサ • × バンク単線式 マルチプレクサ • × バンク 線式 マルチプレクサ NI TB-2627 を取り付ける順番については、 『...
Page 25
端子台を取り付ける NI TB-2627 NI PXI/PXIe-2527 端子台を のフロントパネルに接続するに は、次の手順に従います。 NI PXI/PXIe-2527 メモ はすでに シャーシに取り付けられている必要があります。 NI TB-2627 NI PXI/PXIe-2527 を のフロントコネクタに差し込みます。 端子台の後部パネル背面にある上下のシャーシ用ネジを締めて、端子 台をしっかりと固定します。 I - 2 NI TB-2627 NI PXI-2527 シャーシ用ネジ フロントコネクタ 5 NI TB-2627 図 端子台を取り付ける NI TB-2627 ni.com/jp 取り付け手順 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...