INSTALLATION GUIDE
BNC-2111
BNC Accessory for M Series and E Series Devices
This installation guide describes how to install and configure your
BNC-2111 accessory. If you have not already installed your DAQ device,
refer to the DAQ Quick Start Guide for instructions.
The BNC-2111 is an adapter you can connect to data acquisition (DAQ)
devices. The BNC-2111 includes 24 BNC connectors that allow
connections for 16 single-ended analog input signals, 2 analog output
signals, 5 digital I/O / programmable function input (PFI) signals, and the
external reference voltage for analog output. The BNC-2111 also includes
a single two-position switch for selecting between floating source and
ground-referenced analog input signals.
National Instruments offers two versions of the BNC-2111:
With metal enclosure
Without metal enclosure (board only)
Both versions of the BNC-2111 are suitable for desktop use. An optional
DIN rail-mounting kit for the BNC-2111 with metal enclosure is available
from NI.
The available signals on the BNC-2111 are listed in the
section. If your application requires differential connections or other digital
signals, consider other NI products such as the BNC-2090, BNC-2110,
BNC-2115, or BNC-2120.
The BNC-2111 has one 68-pin connector to connect to your DAQ device.
The BNC-2111 is ideal for simplifying connections between your
measurement apparatus and your DAQ device in laboratory, test, and
production environments.
Specifications

Advertisement

loading
Need help?

Need help?

Do you have a question about the BNC-2111 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments BNC-2111

  • Page 1 BNC-2111 accessory. If you have not already installed your DAQ device, refer to the DAQ Quick Start Guide for instructions. The BNC-2111 is an adapter you can connect to data acquisition (DAQ) devices. The BNC-2111 includes 24 BNC connectors that allow...
  • Page 2 (CTR 1 OUT) APFI 0/ AI11 (AO EXT REF) 1 Floating Source (RSE)/ 3 BNC Center Pin Ground-Referenced Source (NRSE) Switch 4 BNC Shield 2 BNC Connectors Figure 1. BNC-2111 Front Panel (Shown with Metal Enclosure) BNC-2111 Installation Guide ni.com...
  • Page 3: What You Need To Get Started

    M Series or E Series Multifunction DAQ Device For detailed specifications for the BNC-2111, refer to the Specifications section. Do not connect the BNC-2111 to any device other than the National Instruments Caution devices listed in the Choosing a Cable section.
  • Page 4 NI-6070E/DAQPad-6070E PCI-MIO-16E-1 PCI-MIO-16E-4 PCI-MIO-16XE-10 PCI-MIO-16XE-50 Table 3. Double 68-Position VHDCI I/O Connector—32 AI Channels DAQ Device Connector Diagram NI 6224/6229 SHC-68-68-EPM Cable BNC-2111 NI 6254/6259 Connector 1 NI 6284/6289 DAQ Device Connector 0 BNC-2111 SHC-68-68-EPM Cable BNC-2111 Installation Guide ni.com...
  • Page 5 SHC-68-68-EPM Cable Table 5. 100-Pin Female 0.050 D-Type I/O Connector DAQ Device Connector Diagram NI 6025E MIO-16 Leg BNC-2111 NI 6031E/6033E SH100-68-68 Cable NI 6071E DAQ Device BNC-2115 or other Extended I/O Leg accessory © National Instruments Corporation BNC-2111 Installation Guide...
  • Page 6 If you have not already installed your DAQ device, refer to the DAQ Quick Start Guide for instructions. Place the BNC-2111 near the host computer or use the optional DIN rail-mounting kit, which you can order from National Instruments. The DIN rail-mounting kit can only be used with the BNC-2111 with metal enclosure.
  • Page 7 The BNC-2111 is not designed for input voltages greater than 42 V. Input voltages greater than 42 V can damage the BNC-2111, any device connected to it, and the host computer. Overvoltage also can cause an electric shock hazard for the operator.
  • Page 8: Measuring Ground-Referenced Signals

    Connecting Signals to the BNC-2111 This section describes how to configure the BNC-2111. Refer to the Specifications section for a list of available signals on the BNC-2111. With NI-DAQmx, National Instruments has revised its terminal names so they are Note easier to understand and more consistent among NI hardware and software products.
  • Page 9 – – AI GND AI SENSE – – AI GND AI GND Floating Source Ground-Referenced Source Figure 2. BNC-2111 Signal Source Types AI 0 AI 1 AI 14 AI 15 AI SENSE AI GND RSE/NRSE Selector Switch Figure 3. AI Channels 0–15 Connections ©...
  • Page 10 Figure 4 shows these connections. Refer to Table 6 in the Specifications section for more information. AO 0 AO GND AO 1 APFI 0 PFI 0/P1.0 PFI 2/P1.2 D GND PFI 7/P1.7 PFI 12/P2.4 PFI 13/P2.5 Figure 4. AO and PFI Connections BNC-2111 Installation Guide ni.com...
  • Page 11 Specifications This section lists the specifications of the BNC-2111. These specifications are typical at 25 °C unless otherwise specified. Table 6. BNC-2111 Available Signals BNC Connector M Series Function E Series Function AI<0..15> AI<0..15> AI<0..15> AO<0..1> AO<0..1> AO<0..1> APFI 0...
  • Page 12 CTR 1 OUT D GND PFI 7/P1.7 D GND PFI 7/AI SAMP PFI12/P2.4 D GND CTR 0 OUT D GND D GND D GND E Series M Series NC = No Connect Figure 5. BNC-2111 Pin Assignments BNC-2111 Installation Guide ni.com...
  • Page 13 Relative humidity ........5 to 90%, noncondensing Altitude........... 2,000 m Pollution Degree ........2 (Indoor use only) Safety The BNC-2111 meets the requirements of the following standards for safety and electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 •...
  • Page 14: Where To Go For Support

    , search by model number or product line, and click the ni.com/certification appropriate link in the Certification column. Where to Go for Support The National Instruments Web site is your complete resource for technical support. At you have access to everything from ni.com/support troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.
  • Page 15 South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 0 8 587 895 00, Switzerland 41 56 200 51 51, Taiwan 886 02 2377 2222, Thailand 662 992 7519, United Kingdom 44 0 1635 523545 © National Instruments Corporation BNC-2111 Installation Guide...
  • Page 16 Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents.