National Instruments PXI TB-2705 Installation Manual
National Instruments PXI TB-2705 Installation Manual

National Instruments PXI TB-2705 Installation Manual

Terminal block for e series and waveform generation devices

Advertisement

Quick Links

INSTALLATION GUIDE
TB-2705 PXI T
W
AND
AVEFORM
Introduction
What You Need to Get Started
PXI
, National Instruments
, and ni.com
trademarks or trade names of their respective companies.
322909A-01
ERMINAL
G
ENERATION
This installation guide describes how to install and connect signals to
the TB-2705 terminal block for use with PXI E Series and waveform
generation devices.
The TB-2705 is a terminal block assembly consisting of a printed circuit
board, 62 screw terminals, and a plastic enclosure with a strain relief. The
terminal block assembly connects directly to the front panel of National
Instruments E Series and waveform generation devices, eliminating the
need for an external cable.
The TB-2705 allows you to easily connect analog input, analog output,
counter-timer, and digital I/O signals to your National Instruments device.
The 62 screw terminals allow access to every pin on the device with the
exception of some digital ground signals that are common to one another.
The TB-2705 also has a shielded strain-relief to secure your I/O wires and
provide an adequate chassis-ground connection.
You need the following to set up and use your terminal block:
TB-2705 Terminal Block Assembly
TB-2705 PXI Terminal Block for E Series and Waveform Generation
Devices Installation Guide
One of the following:
PXI E Series device
waveform generation device with a 68-pin I/O connector
are trademarks of National Instruments Corporation. Product and company names mentioned herein are
© Copyright 2000 National Instruments Corp. All rights reserved.
B
LOCK FOR
D
EVICES
E S
ERIES
November 2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXI TB-2705 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments PXI TB-2705

  • Page 1 ™ ™ , National Instruments , and ni.com are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 322909A-01 © Copyright 2000 National Instruments Corp. All rights reserved. November 2000...
  • Page 2: Safety Information

    If the device is damaged, turn the device off and do not use it until service-trained personnel can check its safety. If necessary, return the device to National Instruments for service and repair to ensure that its safety is not compromised.
  • Page 3: Signal Descriptions

    Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure that its safety features are not compromised.
  • Page 4 Table 1. TB-2705 Terminal Block E Series Signal Descriptions (Continued) Signal Name Reference Direction Description AISENSE AIGND Input Analog Input Sense—This terminal serves as the reference node for any of channels ACH <0..15> in NRSE configuration. DAC0OUT AOGND Output Analog Channel 0 Output—This terminal supplies the voltage output of analog output channel 0.
  • Page 5 DGND Input PFI2/Convert—As an input, this is one of the PFIs. Output As an output, this is the CONVERT* signal. A high-to-low edge on CONVERT* indicates the start of an A/D conversion. © National Instruments Corporation TB-2705 PXI Terminal Block...
  • Page 6 Table 1. TB-2705 Terminal Block E Series Signal Descriptions (Continued) Signal Name Reference Direction Description PFI3/GPCTR1_ DGND Input PFI3/Counter 1 Source—As an input, SOURCE this is one of the PFIs. Output As an output, this is the GPCTR1_SOURCE signal. This signal reflects the actual source connected to general-purpose counter 1.
  • Page 7 I/O connector as well as the reference for the +5 VDC supply. DIO<0..7> DGND Input or Digital I/O Signals—DIO6 and 7 can Output control the up/down signal of general-purpose counters 0 and 1, respectively. © National Instruments Corporation TB-2705 PXI Terminal Block...
  • Page 8 Table 2. TB-2705 Terminal Block Waveform Generation Signal Descriptions (Continued) Signal Name Reference Direction Description +5 V DGND Output +5 VDC Source—These pins are fused for up to 1 A of +5 V supply. The fuse is self-resetting. EXTREF AOGND Input External Reference—This is the external reference input for the analog...
  • Page 9 0. GPCTR0_OUT DGND Output Counter 0 Output—This is the general-purpose counter 0 output. FREQ_OUT DGND Output Frequency Output—This is the frequency generator output. © National Instruments Corporation TB-2705 PXI Terminal Block...
  • Page 10: Connecting The Signals

    Connecting the Signals See your PXI E Series User Manual or waveform generation device user manual for examples of how to connect your signals. Refer to Figure 1 as you perform the following steps to connect signals to your terminal block. 1 Cover 4 Chassis Connection Screws 7 Chassis Ground Tab...
  • Page 11 DIO5 DIO6 AOGND DIO2 DIO7 DIO3 DGND SCANCLK EXTSTROBE PFI0/TRIG1 DGND PFI1/TRIG2 PFI2/CONVERT PFI3/GPCTR1_SOURCE PFI4/GPCTR1_GATE DGND GPCTR1_OUT PFI5/UPDATE PFI6/WFTRIG PFI7/STARTSCAN DGND PFI8/GPCTR0_SOURCE PFI9/GPCTR0_GATE GPCTR0_OUT DGND FREQ_OUT Figure 2. E Series Device Overlay © National Instruments Corporation TB-2705 PXI Terminal Block...
  • Page 12 PIN# SIGNAL PIN# SIGNAL DAC6 OUT PIN# SIGNAL AOGND AO GND AOGND DAC5OUT AO GND DAC4OUT AO GND AOGND AO GND AOGND AOGND AOGND AOGND DAC3OUT DAC7OUT DIO4 AOGND AOGND DIO0 AOGND AOGND DIO1 DAC1OUT DAC2OUT DGND EXTREF AOGND DGND AOGND DAC0OUT DIO5...
  • Page 13: Installing The Terminal Block

    You must install the TB-2705 terminal block on the PXI module after the module is installed in the chassis. Guide the terminal block onto the switch module connector. Tighten the two terminal block mounting screws. © National Instruments Corporation TB-2705 PXI Terminal Block...
  • Page 14 Input voltages greater than 42 V can damage the TB-2705, any device connected to it, and the host computer. Overvoltage can also cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse.
  • Page 15: Specifications

    Table 1 Note To ensure full EMC and EMI compliance only operate equipment under test (EUT) with shielded cabling. See the Declaration of Conformity for this product for any additional regulatory compliance information. © National Instruments Corporation TB-2705 PXI Terminal Block...
  • Page 16: Technical Support Resources

    Technical Support Resources NI Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section of ni.com...