Page 1
® Reactor Connect 3A5538F For Reactor 2 Electric and Hydraulic Systems For remotely changing system settings on Graco Reactor 2 E-30, E-XP2, H-30, H-40, H-50, H-XP2, and H-XP3 systems. For professional use only. Model 25M777 Model 25P159 Important Safety Instructions Read all warnings and instructions in this manual ®...
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
1. Shut down the system. See your Reactor 2 Disconnect Cellular Module, page 11. operation manual for shutdown instructions. The Reactor Connect allows the Graco Reactor 2 to be 2. Disconnect incoming power at the source. monitored and operated remotely. The Reactor 2 is intended to be controlled by an on-site operator.
Setup Setup Download the Graco Reactor Connect on the Apple App ® ™ Store or the Android Google Play store. 1. Open the Reactor Connect on your smartphone. 2. Read and accept the Terms of Use and data usage notification.
Operation Operation Reactor Connect Ref. Description Ref. Description Proportioner Start/Stop Switch Reactor Status Proportioner Mode (Spray, Jog, Park) Reactor Name Pump Pressure Menu Pump Pressure Setpoint Reactor Power Switch Material Usage Heat Zone Settings Cycle Count Heat Zone On/Off Reset Cycle Count Heat Zone Actual Temperature Heat Zone Temperature Setpoint 3A5538F...
3. Reconnect your app to the Reactor. See Connect App to Reactor, page 8. NOTE: After resetting your Reactor key, all operators using the Graco Reactor Connect must reconnect to the Reactor. NOTE: For security of wireless control, change the Reactor key on a regular basis and whenever there is a concern about unauthorized access.
Troubleshooting Troubleshooting Disconnect Cellular Module NOTE: Before troubleshooting the Reactor, disconnect the cellular module (A) from the ADM. The Reactor Connect cannot change Reactor 2 settings while the For information on troubleshooting a Reactor, refer to cellular module is disconnected. the Reactor repair manual.
Parts Parts Cellular Module and Antenna Accessories Ref. Part Description Qty. 25M833 KIT, cellular module, worldwide 25E658 KIT, cellular module, United States Part Description and Canada only 25D878 KIT, antenna, external use (not shown) 25M830 CABLE, antenna 25M828 ANTENNA, paddle 127158 NUT, 8-32 123422 CABLE, can 16X129 SCREW, phillips, 8-32, 3/2 long...
Technical Specifications Technical Specifications Cellular Module (25M720) FCC/IC Contains FCC ID XPY1CGM5NNN Contains IC ID (Industry Canada) 8595A-1CGM5NNN The enclosed device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.