short circuit state under the factory state (an external short circuit plug shown as Figure 2).
(Illustration: the socket number in circuit is subject to the actual serial number of PCB.)
1)
When using the room card control, the user cuts off the short wire shown in Figure 2 and connects the red
lines to the control switch (supplied by user), and the connecting wire should be 22AWG or above specification. The
switch is closed under normal conditions and off under abnormal conditions.
2)
When using the fire protection , the user cuts off the short wire shown in Figure 2 and connects the White lines
to the control switch (supplied by user), and the connecting wire should be 22AWG or above specification. The switch
is closed under normal conditions and off under abnormal conditions.
3)
When using the ON/OFF function, the user cuts off the short wire shown in Figure 2 and connects the White
lines the ON/OFF control switch (supplied by user), and the connecting wire should be 22AWG or above specification.
In normal conditions, the machine starts once the switch is closed and the machine shuts down once the switch is off.
4 Setting method
This machine defaults that the room card control is effective, which can be switched between the room card control
and ON/OFF function through wire controller. The specific operations are as follows:
Fig.2 YXE-C01U/ YXE-C02U(E)
The EE address number of ON/OFF function is 25:first enter the parameter number 17, and then adjust to the EE address number
25.
Fig. 1
Fig.3 YXE-D01U(E)
Fig.4 YXE-A03U(E)
60