Hisense AS-09TR2SYDDX01 Service Manual page 58

Table of Contents

Advertisement

43
44
45
46
47
48
49
50
Note: the AD value in the table is calculated on the basis of the pull-down resistor is 6.8K.
6-4. Compressor
Drawings attached:
Test in resistance.
TOOL: Multimeter.
Test the resistance of the winding. The compressor is fault if the resistance of winding 0(short
circuit)or∞(open circuit)
Familiar trouble: 1)Compressor motor lock. 2)Discharge pressure value approaches static pressure
value .3)Compressor motor winding abnormality.
Notes:1)Don't put a compressor on its side or turn over.
2) Please assembly the compressor in your air conditioner rapidly after removing the plugs. Don't
place the comp. In air for a long time.
3) Avoiding compressor running in reverse caused by connecting electrical wire incorrectly.
4) Warning! In case AC voltage is impressed to compressor, the compressor performance will be lower
because of its rotor magnetic force decreasing.