Hisense AS-09TR2SYDDX01 Service Manual page 17

Table of Contents

Advertisement

△ Choose a place as cool as possible.
△ Choose a place that is well ventilated.
△ Allow enough room around the unit for air intake or exhaust and possible maintenance. (see a1,
b1 & c1)
△ Provide a solid base (level concrete pad, concrete block, 10 × 40 cm beams or equal), a
minimum of 10 cm above ground level to reduce humidity and protect the unit against possible
water damage
and decreased service life.
△ If the installation bag has rubber pads, it is strongly recommended for use to reduce vibration
and noise.
△ Use lug bolts or equal to bolt down unit, reducing vibration and noise.
a1
Recommended Wire Diameter:
Capacity size
5K~12k
18k
22K~30K
b1
Wire Diameter(mm
1.0(Power wire)/1.0(Connect wire)
2.5(Power wire)/1.5(Connect wire)
2.5(Power wire)/2.5(Connect wire)
)
Fuse or Circuit Breaker Capacity
2
17
c1
3.15A(indoor)/15A(outdoor)
3.15A(indoor)/20A(outdoor)
3.15A(indoor)/30A(outdoor)