Display: 3-1/2–digit LCD (1999 maximum count)
Overrange Indication: "1" appears on the left side of the display
Polarity Indication: "–" appears for negative values
Sampling Rate: Approximately 2.5 per second
Fuse: 200 mA/250 V F, interrupting rating 1.5 kA, 5 x 20 mm
Overvoltage Protection Category:
+ Terminal: Category II, 300 VAC and 300 VDC
Operating Conditions: 0 C to 40 C (32 F to 104 F),
0% to 80% relative humidity
Elevation: 2000 m (6500') maximum
Indoor use only
Storage Conditions: –20 C to 55 C (–4 F to 131 F),
0% to 80% relative humidity
Remove battery
Pollution Degree: 2
Battery: 9 V battery (NEDA 1604, JIS 006P or IEC 6LR61)