Compliance - Teledyne DALSA Piranha 2 P2-2x-40 Series User Manual

Table of Contents

Advertisement

49
h
h
Example: An acqu isition system has a 512 x 512 elem ent, 10m p ixel pitch area scan
cam era, a lens w ith an effective focal length of 45m m , and requ ires that 100m in the
object sp ace correspond to each pixel in the im age sensor. Using the p reced ing equ ation,
the object d istance m u st be 450m m (0.450m ).

4.3 Compliance

The Piranha 2 cam eras have been d esigned for EMC com pliance. The test setu p has been
verified to the follow ing EMC stand ard s:
CISPR-22:1997
EN 50082-1:1997
EN 61000-4-2; ±6kV CD, ±8kV AD:1995
EN 61000-4-3; 3V/ m :1996
EN 61000-4-4; 500V, 1100V:1995
Follow these specific gu id elines to ensu re best perform ance:
Keep Cam era Link cables as short as p ossible.
Ensu re that all cable shield s have 360 electrical connection to the connector.
Fasten and secu re all connectors.
03-032-00493-14
f
This is the governing equ ation for m any object and im age plane
param eters.
OD
10
m
45
mm
OD
450
100
m
OD
mm
( .
0 450
m
)
Piranha 2 User's Manual
Teledyne DALSA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents