Maintenance - Greenlee 93-70 Operating, Maintenance And Safety Instructions

Digital multi-tester
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE

General
Keep unit clean and dry.
Wipe clean with a damp cloth. Let dry completely before using.
Battery Condition
Battery level is low when BAT appears on display.
Battery Replacement (Fig. 2)
1. Disconnect test leads from item being tested and turn meter off. Unplug leads from front
terminals. Remove unit from protective holster.
2. Position meter face down on clean, flat surface. Remove the four screws from case back.
3. Gently lift the case back off of the case front.
4. Lift the battery holder out of the case front and carefully unsnap the battery from the
connector.
5. Install new battery. Replace battery holder in case front. Check leads so that they will not
be pinched when case is reassembled.
6. Make sure all gaskets are properly seated and replace case back. Replace the screws and
tighten firmly. Be careful not to overtighten.
12
Battery
9V
Case Back
Case Front
Fig. 2