Operation; Maintenance - Greenlee TC1S Instruction Manual

Test unit kit

Advertisement

Operation

1. Assemble the force sensor load cell into the adapter.
2. Place the force-sensing adapter on the fixed end, as
a die would be installed.
Note: The ECCX tools require a UA22 die adapter.
3. Turn on the TC1S Digital Indicator.
4. Press F to set the TC1S to measure force.
5. Press Clear to remove the last stored peak force.
6. Cycle the Greenlee tool.
• The peak force is the lower reading.
• The current force is the upper reading.
7. Press Clear and repeat step 6.
8. Press Output to see the peak value of all crimping
cycles.
Unit of Measure Change
1. Press SI/US.
2. Use
to select "units".
3. Press Prog/Enter.
4. Use
to select "SI" or "US" units.
5. Press Prog/Enter to confirm selection.
Greenlee / A Textron Company

Maintenance

Do not attempt to repair this unit. It contains no
user-serviceable parts.
Failure to observe this precaution may result in injury
and may damage the unit.
Cleaning
Periodically wipe the case with a damp cloth and mild
detergent; do not use abrasives or solvents.