Greenlee 93-602 Instruction Manual page 12

Testing multimeter
Table of Contents

Advertisement

Available languages

Available languages

Accuracy
See the Specifications section for operating conditions.
Accuracy is specified as follows:
at 18 C to 28 C (64 F to 82 F), 0% to 80% relative humidity.
Accuracy Table
Value
DC Voltage
AC Voltage*
1.999 mA
DCA
19.99 mA
199.9 mA
1.999 k
Resistance
19.99 k
199.9 k
1.999 M
*Frequency range: 50 Hz to 500 Hz
Diode Test
Test Current:
1.2 mA (approximate)
Open Circuit Voltage:
2.8 V (approximate)
12
(a percentage of the reading + a fixed amount)
Range
Accuracy
1.999 V
(0.8% + 0.001 V)
19.99 V
(0.8% + 0.01 V)
199.9 V
(0.8% + 0.1 V)
600 V
(0.8% + 1 V)
199.9 V
(1.2% + 0.3 V)
600 V
(1.2% + 3 V)
(1% + 0.001 mA)
(1.5% + 0.01 mA)
(1.5% + 0.1 mA)
199.9
(1.2% + 0.2 )
(1.0% + 0.002 k )
(1.0% + 0.02 k )
(1.0% + 0.2 k )
(1.0% + 0.002 M )
Input Impedance
1 M
450 k
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents