Hardwired Setup - Whale INSTANT MATCH SDS263T Installation Manuallines

With bluetooth wireless technology kit
Table of Contents

Advertisement

Hardwired Set Up
mbing of the Waste Pipe
The Whale Instant Match
can be connected to the Mira Advanced Flex Extra
(J09N) shower by means of a hard wired connection.
Set up
1. Whale Instant Match
(SDS236T) set up
Connect the signal wire to the left hand side signal block as
+
~
shown
Red
Brown
• Ensure that that your transformer is set to be used with a
hardwire connection: the flow sensor setting should be set to
6 for "Mira Wired" and the pipe inlet diameter should be set
to 1 for 15mm.
2. Shower Settings
• Please ensure that the "Pump LK1" switch inside the Mira
Advance (J09N) has been set to the "OFF" position as per
the diagram shown.
NOTE: Switch settings for other Whale transformers can be
found on page 17.
16
®
transformer (SDS236T)
®
Transformer
Black
OFF
ON
BEAB CARE MODE
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE