Hardwired Set Up
mbing of the Waste Pipe
The Whale Instant Match
can be connected to the Mira Advanced Flex Extra
(J09N) shower by means of a hard wired connection.
Set up
1. Whale Instant Match
(SDS236T) set up
Connect the signal wire to the left hand side signal block as
+
~
shown
Red
Brown
• Ensure that that your transformer is set to be used with a
hardwire connection: the flow sensor setting should be set to
6 for "Mira Wired" and the pipe inlet diameter should be set
to 1 for 15mm.
2. Shower Settings
• Please ensure that the "Pump LK1" switch inside the Mira
Advance (J09N) has been set to the "OFF" position as per
the diagram shown.
NOTE: Switch settings for other Whale transformers can be
found on page 17.
16
®
transformer (SDS236T)
®
Transformer
⬇
Black
OFF
ON
BEAB CARE MODE
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE