Fault Diagnosis - Whale INSTANT MATCH SDS263T Installation Manuallines

With bluetooth wireless technology kit
Table of Contents

Advertisement

Whale INSTANT MATCH
Ensure power is connected and switched on.
Press the TEST button on top of the transformer.
NO
Check unswitched spur connections are
good and insulation has not been pinched.
Check fuses and RCDs are ok.
If no obvious fault, attach plug to
transformer mains lead and plug into
known good socket.
Does lamp illuminate?
NO
Replace transformer
SDS236T (755.678)
24
Pump will not start
Does the buzzer beep?
Does Pump Start when TEST
button is pressed & released?
NO
Cut off spade connectors
and reconnect with
YES
connector block, RED
to RED and BLK to BLK.
Retest. Does pump work?
Check the
NO
dwelling wiring,
fuses and RCDs.
If 10 - 20v on pump terminals
re-check polarity on pump.
If correct change
the pump (SDS021T)
Kit Fault Diagnosis
®
YES
YES
YES
Check that the "LK2" switch inside
the shower has been set to ON.
Ensure that the transformer has
been set to the Bluetooth setting.
Ensure that the transformer is
located within 5m of the shower.
Carry out the registration process.
YES
No further action
What is the fault?
Pump will not stop
The transformer allows the pump to
over-run for up to 60 seconds.
If the pump continues to run after
this time has elapsed, switch off
the transformer at the mains and
allow it to cool and re-set.
If this does not solve the
problem, replace transformer
SDS236T (755.678)
WIRED
Check transformer setting
is correct for sensor.
Check signal cable between sensor
and transformer is less than 5m
long, undamaged and that
connections are good.
Retest. Does pump work?
BLUETOOTH
Does pump work?
NO
Contact Mira
YES
Contact shower
manufacturer/
replace sensors
NO