Pump Set Up
1.9
A simple set up is all that is required for
trouble-free efficient performance of the
Dry-Deck 20 system.
1.10
How to Adjust Settings:
a. Pressing the '<' or '>' button will switch
between the various menu options, indicated by
the message on the display.
b. The 'up' and 'down' arrows are used to adjust
the value.
c. Press OK '
' key firmly to store value.
Press OK '
' to enter configuration screens.
Follow the sequence of screens and set values as
required to complete setup.
1. Language: English is the default language. For
other options use 'up' and 'down' arrows.
2. Sensor Type: Select Sika sensor.
S e n s o r
T y p e
S I K A
3. Pump Speed:
This sets the speed of the pump in relation to the
flow rate from the sensors.
Prior to making adjustments turn the shower on
and wait until the pump runs. Set the shower flow
rate in the range 6-9 ltrs/min as indicated on the
display.
Note: For pumped showers use the lowest flow rate to
set the Pump speed. This may be outside the band 6-9
ltrs/minute.
Watch the level of water within the shower
using the gulley cover as a guide. If the water
level is falling reduce the speed of the pump by
pressing the 'down' arrow. Use initial changes of 5
until fine tuning is required. If the water level is
rising make changes in blocks of 5 to increase the
speed of the pump by using the 'up' arrow.
After making a change watch the water level.
Wait at least 30 seconds, as the system
needs to stabilise, until you see if the water is
rising or falling. When the water level is slightly over
pumping, store the speed setting by firmly pressing
the OK '
O K
' button.