Web screen configurations (continued)
z IPv6 network
Manual [On, Off]
Enable or disable manual configuration of the IPv6 address.
On
Enter the IPv6 address manually.
Off
Disable manual entry of the IPv6 address.
Factory settings: Off
IP address(IPv6)
When [Manual] is set to [On], the IPv6 address must be entered
manually.
Be sure to enter an address unique from other devices.
<NOTE>
• When connecting to the manually specified IP address through a
router, use an IPv6-compatible router, and enable the automatic
configuration function for the IPv6 address. Be sure to configure
an IPv6 address that includes the prefix information provided
by the IPv6-compatible router. For details, refer to the operating
instructions for the router.
• Link local address cannot be set.
Default gateway
When [Manual] is set to [On] for [IPv6 network], enter the default
gateway for the unit's IPv6 network.
Factory settings: blank
<NOTE>
• It is not possible to set the default gateway when [DHCPv6] is [On].
DHCPv6 [On, Off]
Enable or disable use of the IPv6 DHCP function.
Configure the DHCP server so that the same IP address is not
configured for a personal computer that does not use the DHCP
function and other network cameras. For details on server settings,
consult your network administrator.
On
Use the IPv6 DHCP function.
Off
Do not use the IPv6 DHCP function.
Factory settings: Off
DNS [Auto, Manual]
Set whether the DNS server address is to be acquired automatically
(Auto) or to be manually input (Manual).
The DNS setting needs to be performed if [Manual] is set.
When using the DHCP function, if you set to [Auto], then the DNS server
address will be acquired automatically.
Consult the system administrator regarding the settings.
Factory settings: Manual
Primary server address
Secondary server address
Enter the IPv4/IPv6 address of the DNS server.
For details on the IPv4/IPv6 address of the DNS server, consult your
system administrator.
z Common (to IPv6/IPv4)
HTTP port [1 to 65535]
Port numbers are allocated separately.
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 546,
547, 554, 995, 5960 to 5985, 7960 to 8060, 10669, 10670, 11900,
59000 to 61000
Factory settings: 80
Max RTP packet size [Unlimited‑1500byte,
Limited-1280byte]
Specify whether to limit the size of RTP packets sent from the camera
when using RTP to view camera images.
Unlimited-1500byte
Limited-1280byte
Factory settings: Unlimited-1500byte
Normally, it is recommended that the [Unlimited-1500byte] setting be
used.
Select [Limited-1280byte] when the packet size of the used
communication line is limited. For details on the maximum packet size
of communication lines, consult your network administrator.
HTTP max segment size (MSS) [Unlimited(1460byte),
Limited(1280byte), Limited(1024byte)]
Select whether to limit the maximum segment size (MSS) transmitted
by a camera when viewing camera images using HTTP.
Unlimited(1460byte)
Limited(1280byte)
Limited(1024byte)
Factory settings: Unlimited(1460byte)
Normally, it is recommended that the default setting be used.
Select [Limited(1024byte)]/[Limited(1280byte)] when the maximum
segment size (MSS) of the used communication line is limited. For
details on the maximum segment size (MSS) of communication lines,
consult your network administrator.
142
Unlimited (1500 byte)
Limited (1280 byte)
Unlimited (1460 byte)
Limited (1280 byte)
Limited (1024 byte)