Summary of Contents for Cross Technologies 2415-x02
Page 1
Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
+24 VDC option V1, can be inserted only on the channel 1 RF line. The 2415-402 is powered by a 100-240 ±10% VAC, 47-63 Hz power supply, and is contained in a 1 3/4” X 19” X 16” rack mount chassis. * 2415-x02, Four (4) Channels, 2415-302, Three (3) Channels, 2415-202, Two (2) Channels, 2415-102, One (1) Channel. MODEL 2415...
TABLE 1.0 2415-x02 Multi-Channel Upconverter Technical Specifications** Input Characteristics Impedance/Return Loss 75Ω/18 dB (See Table 2.2 for connector options) Frequency 70 ±18 MHz Input Level Range -35 to -10 dBm Output Characteristics 75Ω / 12 dB (See Table 2.2 for connector options)
Page 5
140 ±36/70 ±18 MHz Selectable x = Number of Channels X1002 - x 1 kHz Frequency Step Size Connectors/Impedance See TABLE 2.2 **+10˚C to +40˚C; Specifications subject to change without notice Cross Technologies, Inc. 2015 2415-x02 Manual, Rev. E Page 5 09/28/17...
A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485) M&C Cable Diagram - Cross Technologies Frequency Converters Male DB-9 Female DB-9 2415-x02 M&C Port...
Page 7
B) Status Requests Table 1.1 lists the status requests for the 2415-x02 and briefly describes them. P P LEASE NOTE: Status requests of values specific to a channel must be preceded by a *i where *i is the channel number.
Page 8
• d=channel 4 alarm state (0 for alarm off; 1 for alarm on) Get product/model info {aaSV} Returns {SV2415-x02xxxver5.00} where: • 2415-x02 = product model • xxx = list of options, if any •"ver"=separates model & options from firmware version • 5.00 = firmware version 2415-x02 Manual, Rev.
Page 9
(C) Commands Table 1.2 lists the commands for the 2415-x02 and briefly describes them. After a command is sent the 2415-x02 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where:...
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2415-x02 Manual, Rev. E Page 10 09/28/17...
2.1 Mechanical The 2415-x02 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 2415-x02 can be secured to a rack using the 4 holes on the front panel.
Does not function channels 1, 2, 3, & 4. normal display mode. in the normal display mode. FIGURE 2.3 2415-x02 Front Panel Controls and Indicators FRONT PANEL (2415-402 - Four Channel show above) 2415-x02 Manual, Rev. E Page 13 09/28/17...
2.4 Operation 2.4.1 Installing and Operating the 2415-x02 Upconverter 1. Connect a -35 dBm to -10 dBm signal to IF IN, for the designated channel (ie: J1, J5, J7, J9), (Figure 2.2). 2. Connect the RF OUT, for the designated channel (ie: J2, J6, J8, J10), to the external equipment, (Figure 2.2).
Page 15
During frequency, gain changes, the vertical movement will raise or lower the number in the direction of the arrows (Figure 2.3). b. For other functions such Mute on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 2415-x02 Manual, Rev. E Page 15 09/28/17...
Page 16
See Figure 2.5 for the sequence of menu options. NOTE: THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS. HOWEVER, THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW. 2415-x02 Manual, Rev. E Page 16 09/28/17...
SAVE SETTINGS Menu 6 Reference Insert REF INSERT = OFF SCROLL Save? When “R” is selected SAVE SETTINGS from any above menu or at the end. REPEAT ABOVE SEQUENCE FOR ALL INDIVIDUAL CHANNELS 2415-x02 Manual, Rev. E Page 17 09/28/17...
Contact Cross Technologies for the SNMP MIB file. 3.1 Connection 3.1.1 Direct Connection to a PC For control from a local PC, attach the 2415-x02 Ethernet port to the Ethernet network connector on the PC using a crossover RJ-45 cable. 3.1.2 LAN Connection For LAN connections, attach the 2415-x02 Ethernet port to the LAN using a normal RJ-45 cable.
Page 19
Network to display the Network Settings screen. Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 192.168.123.2 (Default)). Click “Apply Settings” in the left frame to apply the new settings in the network device. 2415-x02 Manual, Rev. E Page 19 09/28/17...
Page 20
Figure 3.2: Network Settings Web Page Screen (Example above shows Network Settings Screen for Model 2415-402) 2415-x02 Manual, Rev. E Page 20 09/28/17...
Enter the following address in a web browser to access the M&C web page: http://<ip address>/serial/0/setup.htm where <ip address> is the IP address of the 2415-x02. Figure 3.3 (example below) shows the web page from model 2415-402 frequency converter. Figure 3.3: Model 2415-x02 Web Page (Example above shows M&C Web Page for Model 2415-402)
Start the Hyper Terminal application and select “New Connection” from the “File” drop down menu. The next screen is a “Connect To” dialog box. 1. Enter the IP address of the 2415-x02 in the “Host address:” field. 2. Enter 9999 in the “Port Number:” field.
Page 23
If you select Public, access is allowed for any number of authorized IP addresses of SNMP Managers. It is not required to enter IP Addresses of SNMP Managers. Figure 3.5: Device Server Configuration Menu Once you have completed you SNMP set up, select item #9, “SAVE AND EXIT” 2415-x02 Manual, Rev. E Page 23 09/28/17...
Page 24
ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 2415-x02 Manual, Rev. E Page 24 09/28/17...