Cross Technologies 2416 02I Series Instruction Manual

Cross Technologies 2416 02I Series Instruction Manual

Multi channel downconverter

Advertisement

Quick Links

Instruction Manual
2416-402I Four Channel • 2416-302I Three Channel • 2416-202I Two Channel • 2416-102I One Channel
1
2
3
4
ALARMS
REMOTE POWER
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
------ CH 1 -------- ------ CH 2 --------
1674.125
1926.250
1926.375
2086.625
------ CH 3 -------- ------ CH 4 --------
(Shown, Model 2416-402I - Four Channel, Front Panel)
C
T
ROSS
ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
Model 2416-x02I
Multi Channel Downconverter
MODEL 2416
DOWNCONVERTER
MENU
EXECUTE
March 2021, Rev. C
C
T
ROSS
ECHNOLOGIES INC.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2416 02I Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cross Technologies 2416 02I Series

  • Page 1 Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
  • Page 2: Table Of Contents

    All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
  • Page 3: General

    Model 2416-x02I Multi Channel Downconverter 2416-402I Four Channel • 2416-302I Three Channel • 2416-202I Two Channel • 2416-102I One Channel 1.0 General 1.1 Equipment Description The 2416-402I Downconverter has four individual channels, each one converts 950 to 2150 MHz to 70 MHz in 125 kHz steps using PLL in “exact frequency mode”...
  • Page 4: Technical Specifications

    1.2 Technical Specifications TABLE 1.0 2416-x02I Multi-Channel Downconverter Technical Specifications** Input Characteristics Impedance/Return Loss 75Ω/10 dB (See Table 2.2 for connector options) Frequency 950 to 2150 MHz Noise Figure, Max. 15 dB maximum gain Input Level Range -50 to -20 dBm Output Characteristics 75Ω...
  • Page 5 140 ±36/70 ±18 MHz Selectable X1002 - x 1 kHz Frequency Step Size W113 Rear Mounted Cooling Fan Connectors/Impedance See TABLE 2.2 **+10˚C to +40˚C; Specifications subject to change without notice Cross Technologies, Inc. 2021 2416-402I Manual, Rev. C Page 5 03/22/21...
  • Page 6: Monitor & Control Interface

    A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485) M&C Cable Diagram - Cross Technologies Frequency Converters Male DB-9 Female DB-9 2416-x02I M&C Port...
  • Page 7 B) Status Requests Table 1.1 lists the status requests for the 2416-x02I and briefly describes them. P P LEASE NOTE: Status requests of values specific to a channel must be preceded by a *i where *i is the channel number. P P LEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485 is selected.
  • Page 8 (Status Request continued from page 7...) TABLE 1.1 TABLE 1.1 2416-x02I Status Requests Continued 2416-x02I Stat t us Status Requests Co o ntinued Command Syntax* Description Get RF Frequency {aa*iSY} Returns {*iSYx} where : (Option W160/70) • i = 1, 2, 3 or 4... •...
  • Page 9 (C) Commands Table 1.2 lists the commands for the 2416-x02I and briefly describes them. After a command is sent the 2416-x02I sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where: { = start byte aa = address (RS-485 only) C = 1 character, either C (command) or S (status)
  • Page 10: Environmental Use Information

    1.4 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution.
  • Page 11: Installation

    2.0 Installation 2.1 Mechanical The 2416-x02I consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 2416-x02I can be secured to a rack using the 4 holes on the front panel.
  • Page 12: Rear Panel Inputs & Outputs

    BNC, 75Ω BNC, 75Ω BNC, 75Ω BNC, 50Ω BNC, 50Ω BNC, 50Ω BNC, 50Ω Type F, 75 Ω BNC, 50Ω BNC, 75 Ω x = # of Channels Contact Cross Technologies for other options 2416-402I Manual, Rev. C Page 12 03/22/21...
  • Page 13: Front Panel Controls & Indicators

    2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators. DS1 - REMOTE LED LCD FRONT PANEL DISPLAY S1 - MENU/EXECUTE BUTTON Yellow LEDs indicates Shows parameter selection and Press this to get into Program mode remote operation.
  • Page 14: Operation

    2.4 Operation 2.4.1 Installing and Operating the 2416-x02I Downconverter 1. Connect a -50 dBm to -20 dBm signal to RF IN, J2 (Figure 2.2). 2. Connect the RF OUT, J1, to the external equipment. 3. Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel. 4.
  • Page 15 2.5 Power On Settings Figure 2.5 shows the various Front Panel LCD Displays that you will see during the Power Up sequence and the Settings modes. The first two displays (Power Up, displaying Model Number, Rev. Level and IP Address are only displayed briefly during the Power On sequence.
  • Page 16 2.5.2 Frequency Changes At any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do not press the Menu/Execute switch; simply do nothing for approximately 30 seconds, and the system will return to the normal operating mode or scroll to “R”...
  • Page 17: Menu Settings

    2.6 Menu Settings All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over.
  • Page 18: Ethernet Interface

    3.0 Ethernet Interface Installation and Operation (Option W8, W18 or W28) This manual applies to Cross Technologies products equipped with a 10/100 Base-T compatible Ethernet interface for control and monitoring of its operating parameters. The following sections describe the operation and setup of those interfaces.
  • Page 19 Figure 3.1: Configuration Manager Screen (Example above shows Configuration Manger Screen for Model 2416-402I) Once logged in, you will be presented with the Configuration Manager web page. In the left frame of the configuration manager click on Network to display the Network Settings screen. Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 192.168.123.2 (Default)).
  • Page 20 Figure 3.2: Network Settings Web Page Screen (Example above shows Network Settings Screen for Model 2416-402I) 2416-402I Manual, Rev. C Page 20 03/22/21...
  • Page 21: Webpage M&C

    3.3 Web Page M & C Enter the following address in a web browser to access the M&C web page: http://<ip address>/serial/0/setup.htm where <ip address> is the IP address of the 2416-x02I. Figure 3.3 (example below) shows the web page from model 2416-402 frequency converter. Figure 3.3: Model 2416-x02I Web Page (Example above shows M&C Web Page for Model 2416-402I)
  • Page 22: Snmp Configuration

    3.4 SNMP Configuration ® Setting of SNMP parameters such as Community Write and Community Read strings requires a Telnet connection to port 9999. The following instructions explain how to establish such a Telnet connection using Windows XP's utility Hyper Terminal. Start the Hyper Terminal application and select “New Connection”...
  • Page 23 If you select Public, access is allowed for any number of authorized IP addresses of SNMP Managers. It is not required to enter IP Addresses of SNMP Managers. Figure 3.5: Device Server Configuration Menu Once you have completed you SNMP set up, select item #9, “SAVE AND EXIT” 2416-402I Manual, Rev.
  • Page 24 ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 2416-402I Manual, Rev. C Page 24 03/22/21...

This manual is also suitable for:

2416-402i2416-302i2416-202i2416-102i

Table of Contents