This meter has been designed for use with both alkaline and rechargeable Nickel Metal Hydride (NiMH) batteries . No other types are
recommended . The analyzer is supplied with 4 "AA" size alkaline batteries . These should be installed into the instrument as shown in the diagram
indicated on the back of the unit .
Using Re-Chargeable Batteries
The battery charger must only be used when NiMH batteries are fitted . Alkaline batteries are not re-chargeable . Attempting to recharge alkaline
batteries may result in damage to the product and may create a fire risk .
Battery Charging
Ensure that you use the correct charger . This unit uses a 9V DC regulated charger . Ensure that the batteries are fitted in the correct manner, and
then charge for at least 16 hours . Subsequent charges should be overnight . NiMH batteries may be charged at any time, even for short periods
to conduct testing .
Remove the probe from the flue and allow the analyzer to purge
with fresh air until readings return to zero . - O2 to 20 .9%, CO to
Zero (Be careful as the probe tip will be HOT)
While the CO sensor has an expected life of more than five years in normal use it is recommended that the analyzer is re-certified at least annually .
This is so that long-term drift on the sensor and electronics can be eliminated . Local regulations may require more frequent re-calibration and
users should check with appropriate authorities to ensure they comply with relevant guidelines .
Periodically clean your instruments case using a damp cloth . DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or effect the reliability of the structural components .
1.800.561.8187
CAUTION!
Take great care when installing the batteries to observe correct polarity .
Always check the meter for operation immediately after installing
new batteries .
WARNING!
Under NO circumstance should you expose batteries to extreme heat or fire as they may explode and cause injury . Always
dispose of old batteries promptly in a manner consistent with local disposal regulations .
O2% 20.9
COa -0>-
Aux
Status
Menu
CO
2
WARNING!
L O N G L I F E E O S A N A L Y Z E R
Repair and service of this instrument is to be performed by qualified personnel only . Improper repair or service could result in
physical degradation of the instrument . This could alter the protection from personal injury this meter provides to the operator .
Perform only those maintenance tasks that you are qualified to do .
www.
REPLACING THE BATTERIES

POST TEST

O2
CO Air
Eff
CO
2
Free
X-Air
CO
Drain water trap by unplugging
Temp
the drain plug and shake to
Fuel
Date
get excess water out .
Time

PERIODIC SERVICE

C85
CO TEMP
ANNUAL RE-CERTIFICATION

CLEANING

.com
Check particle filter for dirt
and any other sediment and
replace if necessary .