LP GAS CYLINDER (TANK) RUBBER SEAL INSPECTION:
Inspect the propane tank valve rubber seal for cracks, wear
or deterioration prior to use. A damaged rubber seal can
cause a gas leak, possibly resulting in an explosion, fire or
severe bodily harm.
Inspection should be done each time the propane tank is
connected to the grill, has been refilled, exchanged or has
not been used for more than 60 days.
Do not use a propane tank with a damaged rubber seal.
Exchange the tank or have the rubber seal replaced at a
qualified propane filling station.
INSTALLING THE LP GAS CYLINDER (TANK) ONTO THE GRILL:
1. Check that the cylinder valve is closed by turning the knob clockwise. Inspect cylinder valve rubber seal for
cracks or deterioration. Do not use propane tank with damaged seal as a gas leak may occur.
2. Place the cylinder into the tank holder in the bottom of cabinet.
3. Orient the cylinder such that the valve opening faces the left side of the grill, and the hose is not kinked or
damaged.
4. Fully tighten the tank retention screw on the side of tank holder to secure tank.
HOSE & REGULATOR SPECIFICATION AND INSTALLATION:
DO NOT attempt to connect grill, as purchased for LP (propane) gas, to any other fuel supply
source such as a natural gas line. For dual fuel grills that can be converted to natural gas, a
Brinkmann conversion kit must be purchased and installed for use with natural gas. Please
contact Brinkmann Customer Service at 800-527-0717 to see if your grill can be converted.
DO NOT use any other pressure regulator/hose assembly other than the one supplied with your
grill. Replacement pressure regulator/hose assembly must be part No 155-2512-0, which can be
obtained by contacting customer service at 800-527-0717.
DO NOT attempt to adjust or repair a regulator. The regulator is designed to operate at a
maximum output pressure of 11 inches of water column (2.74 kPa).
Ensure the tank valve is CLOSED prior to connecting the LP gas cylinder to your grill. Turn the
valve knob clockwise to properly close the valve. Read and follow all instructions and warnings
on the supply hose safety tags. Read and follow all warnings in this manual concerning the safe
use of LP gas cylinders and the hose and regulator before connecting cylinder to grill. Read and
follow all warnings on the LP cylinder.
Tank Retention
Screw
Tank Holder
WARNING
Good
Rubber Seal
Damaged
Rubber Seal