Pr.
Name
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
Electronic bypass
135
sequence selection
MC switchover interlock
136
time
137
Start waiting time
Bypass selection at a
138
fault
Automatic switchover
139
frequency from inverter
to bypass operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
Speed setting
144
switchover
PU display language
145
selection
Acceleration/
147
deceleration time
switching frequency
Stall prevention level at
148
0 V input
Stall prevention level at
149
10 V input
Output current
150
detection level
Output current
151
detection signal delay
time
Zero current detection
152
level
Zero current detection
153
time
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
157
OL signal output timer
AM terminal function
158
selection
Automatic switchover
frequency range from
159
bypass to inverter
operation
160
User group read

selection

Frequency setting/key
161
lock operation selection 0, 1, 10, 11
Automatic restart after
162
instantaneous power
failure selection
First cushion time for
163
restart
First cushion voltage for
164
restart
Stall prevention
165
operation level for
restart
Output current
166
detection signal
retention time
Output current
167
detection operation
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
Operation hour meter
171
clear
User group registered
172
display/batch clear
173
User group registration 0 to 1999, 9999
174
User group clear
14
PARAMETER LIST
Downloaded from
ManualsNet.com
Setting
Initial
Pr.
range
value
0.1 to 1000%,
STF terminal function
100%
178
9999
selection
0.1 to 3600s,
STR terminal function
1s
179
9999
selection
0 to 100%, 9999 9999
RL terminal function
180
selection
0 to 100%, 9999 9999
RM terminal function
0 to 100%, 9999 9999
181
selection
0.01 to 10s,
9999
RH terminal function
9999
182
selection
0, 1
0
RT terminal function
183
selection
0 to 100s
1s
AU terminal function
184
selection
0 to 100s
0.5s
JOG terminal function
185
selection
0, 1
0
CS terminal function
186
selection
0 to 60Hz, 8888,
9999
9999
MRS terminal function
187
selection
0 to 590Hz
1Hz
STOP terminal function
188
selection
0 to 360s
0.5s
RES terminal function
189
selection
0 to 590Hz
1Hz
RUN terminal function
190
selection
0 to 360s
0.5s
SU terminal function
191
selection
0, 2, 4, 6, 8, 10,
12, 102, 104,
IPF terminal function
4
192
106, 108, 110,
selection
112
OL terminal function
193
selection
0 to 7
FU terminal function
194
selection
0 to 590Hz, 9999
9999
ABC1 terminal function
195
selection
0 to 400%
150%
ABC2 terminal function
196
selection
0 to 400%
200%
232 to
Multi-speed setting (8
0 to 400%
150%
239
speed to 15 speed)
Soft-PWM operation
240
0 to 10s
0s
selection
Analog input display
241
unit switchover
0 to 400%
5%
Terminal 1 added
242
compensation amount
0 to 10s
0.5s
(terminal 2)
Terminal 1 added
0, 1, 10, 11
1
243
compensation amount
(terminal 4)
Cooling fan operation
0, 10
0
244
selection
245
Rated slip
0 to 31, 100, 101 0
Slip compensation time
246
0 to 25s, 9999
0s
constant
1 to 3, 5 to 14,
Constant-power range
17, 18, 21, 24,
247
slip compensation
32 to 34, 36, 46,
selection
1
50, 52 to 54, 61,
Self power
62, 67, 70, 
248
management selection 0 to 2
87 to 98
Earth (ground) fault
249
detection at start
0 to 10Hz, 9999 9999
250
Stop selection
0, 1, 9999
0
Output phase loss
251
protection selection
0
252
Override bias
0 to 3, 10 to 13,
253
Override gain
1000 to 1003,
0
Main circuit power OFF
254
1010 to 1013
waiting time
Life alarm status
0 to 20s
0s
255
display
Inrush current limit
0 to 100%
0%
256
circuit life display
Control circuit capacitor
257
0 to 400%
150%
life display
Main circuit capacitor
258
life display
0 to 10s, 9999
0.1s
Main circuit capacitor
259
life measuring
PWM frequency
0, 1, 10, 11
0
260
automatic switchover
Power failure stop
261
selection
Subtracted frequency at
262
0, 10, 9999
9999
deceleration start
Subtraction starting
0, 9999
9999
263
frequency
Power-failure
9999, (0 to 16)
0
264
deceleration time 1
9999
Power-failure
265
0 to 1999, 9999
9999
deceleration time 2
search engine
Setting
Initial
Name
range
value
60
61
0
1
0 to 20,
22 to 28, 32, 37,
2
42 to 48, 
50 to 53, 
3
57 to 62,
64 to 74,
76 to 80, 85, 
4
87 to 89
92 to 96,
5
128, 129,
9999

6
24
25
62
0 to 8, 10 to 20, 22,
0
25 to 28, 30 to 36,
38 to 57, 60, 61, 63,
64, 67, 68, 70, 79,
1
80, 84, 85, 90 to 99,
100 to 108,
2
110 to 116, 120,
122, 125 to 128,
130 to 136,
3
138 to 157, 160,
161, 163, 164, 167,
168, 170, 179, 180,
4
184, 185,
190 to 199,
99
200 to 208,
211 to 213, 247,
300 to 308,
9999
311 to 313, 347,
9999

0 to 590Hz, 9999
9999
0, 1
1
0, 1
0
0 to 100%
100%
0 to 100%
75%
0, 1, 101 to 105,
1000, 1001, 1101
1
to 1105
0 to 50%, 9999 9999
0.01 to 10s
0.5s
0, 9999
9999
0
0, 1
0
0 to 100s, 
1000 to 1100s,
9999
8888, 9999
0, 1
1
0 to 200%
50%
0 to 200%
150%
1 to 3600s,
600s
9999
(0 to 255)
0
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
100%
0, 1, 11
0
0, 1
1
0 to 2, 11, 12,
0
21, 22
0 to 20Hz
3Hz
0 to 590Hz,
60/50Hz

9999
0 to 3600s
5s
0 to 3600s,
9999
9999
Setting
Pr.
Name
range
Power failure
266
deceleration time
0 to 590Hz
switchover frequency
Terminal 4 input
267
0 to 2
selection
Monitor decimal digits
268
0, 1, 9999
selection
269
Parameter for manufacturer setting. Do not set.
Stop-on contact/load
torque high-speed
270
0 to 3, 11, 13
frequency control
selection
High-speed setting
271
0 to 400%
maximum current
Middle-speed setting
272
0 to 400%
minimum current
Current averaging
0 to 590Hz,
273
range
9999
Current averaging filter
274
1 to 4000
time constant
Stop-on contact
275
excitation current low-
0 to 300%, 9999 9999
speed multiplying factor
0 to 9, 9999
PWM carrier frequency
276
at stop-on contact
0 to 4, 9999
Brake opening
278
0 to 30Hz
frequency
279
Brake opening current
0 to 400%
Brake opening current
280
0 to 2s
detection time
Brake operation time at
281
0 to 5s
start
Brake operation
282
0 to 30Hz
frequency
Brake operation time at
283
0 to 5s
stop
Deceleration detection
284
0, 1
function selection
Overspeed detection
frequency (Excessive
285
0 to 30Hz, 9999 9999
speed deviation
detection frequency)
286
Droop gain
0 to 100%
287
Droop filter time constant 0 to 1s
0 to 2, 10, 11, 
Droop function
288
activation selection
20 to 22
Inverter output terminal
289
5 to 50ms, 9999 9999
filter
Monitor negative output
290
0 to 7
selection
0, 1, 10, 11, 20,
21, 100
291
Pulse train I/O selection
(FM type)
0, 1 (CA type)
Automatic acceleration/
292
0, 1, 3, 5 to 8, 11
deceleration
Acceleration/deceleration
293
0 to 2
separate selection
UV avoidance voltage
294
0 to 200%
gain
Frequency change
0, 0.01, 0.10,
295
increment amount
1.00, 10.00
setting
0 to 6, 99, 
296
Password lock level
100 to 106, 199,
9999
(0 to 5), 
297
Password lock/unlock
1000 to 9998,
9999
Frequency search gain 0 to 32767,
298
9999
Rotation direction
299
detection selection at
0, 1, 9999
restarting
0 to 8, 10 to 20, 22,
313
DO0 output selection

25 to 28, 30 to 36, 
38 to 57, 60, 61, 63,
314
DO1 output selection
64, 68, 70, 79, 

84 to 99, 100 to 108,
110 to 116, 120,
315
DO2 output selection

122, 125 to 128, 
130 to 136, 
316
DO3 output selection

138 to 157, 160,
161, 163, 164, 168,
170, 179, 
317
DO4 output selection

184 to 199, 
200 to 208, 
318
DO5 output selection

211 to 213, 247,
248, 300 to 308, 
311 to 313, 347,
319
DO6 output selection

348, 9999
0 to 8, 10 to 20,
22, 25 to 28, 
320
RA1 output selection

30 to 36, 
38 to 57, 60, 61,
63, 64, 68, 70,
321
RA2 output selection

79, 80, 84 to 91,
94 to 99, 
200 to 208, 
322
RA3 output selection

211 to 213, 247,
248, 9999
Inverter/converter
328
0 to 9999
switching
Initial
value
60/50Hz

0
9999
0
50%
100%
9999
16

9999

3Hz
130%
0.3s
0.3s
6Hz
0.3s
0
0%
0.3s
0
0
0
0
0
100%
0
9999
9999
9999
0
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
0

Advertisement

loading