Connecting the Cash Drawer

Required specifications of cash drawers

Specifications of drawers differ depending on makers or models. When you use a drawer other than specified,
make sure its specification meets the following conditions.
Otherwise, devices may be damaged.
• The load, such as a drawer kick solenoid, must be connected between pins 4 and 2 or pins 4 and 5 of the
drawer kick connector.
• When the drawer open/close signal is used, a switch must be provided between drawer kick connector pins 3
and 6.
• The resistance of the load, such as a drawer kick solenoid, must be 24
1A or less.
• Be sure to use the 24V power output on drawer kick connector pin 4 for driving the equipment.
Drawer Connection Diagram
F.G
Printer side
Adaptable Connector
RJ12 modular connector
• Do not connect both the optional external buzzer and the cash drawer to the printer at the
same time by using a branched connector.
• When using a cash drawer, make sure to set "Select Buzzer" to "Disabled" or "Built-in buzzer"
(see
"Software Settings" on page
• Two driver transistors cannot be energized simultaneously.
• Leave intervals longer than 4 times the drawer driving pulse when sending it continuously.
Drawer kick connector
1
With shielded
2
3
4
+24V
5
6
77).
Ω
or more or the input current must be
Drawer kick
solenoid
Drawer open/
close switch
User side
[Drawer kick side]
Chapter 2 Setup