5 MAINTENANCE

The system is designed for trouble-free operation and generally does not need maintenance. Maintenance
activities should only be carried out by trained personnel if required.
The equipment operation status can be observed remotely through OMT/OMC.
Periodic inspection of the equipment(s) is recommended. The recommended tasks include:
Measurement of the return loss of the feeder system.
Ensure the reliable connection of cables, power cords and facilities located indoor.
Inspect and record operation status and parameters, such as receive signal level, output noise level,
DL output power of the equipment, from the OMC or OMT.
Check the PSU output voltage.
Verify that the actual coverage has not degraded.
Check the controlling and monitoring function.
Verify that lightning and grounding protection is in good condition.
Ensure the labels are clear and legible.
Verify the Li-ion battery status. Deeply discharged battery should be returned to the factory for
replacement. If the battery voltage drops below 16V within one hour, replacement of Li-ion battery is
recommended.
SR-1910 QI
ENU Status : 1-1-1
INSTALLATION GUIDE FOR SR-1910
End of section