Download Print this page

DUROMAX XP10000EH Manual page 16

Hide thumbs Also See for XP10000EH:

Advertisement

AC Operation
1 Start the engine .
2 Turn the voltage selector switch to either position.
With the voltage selector switch in the ''120/240V'' position, you can use the 120V and 120/240V
receptacles simultaneously. If you \ require more 120V only power, then select the "120V only" position
this will disable the 120/240V twist lock plug.
3 Switch the AC circuit breaker ON.
4 Plug in the appliance.
Most motorized appliances require more than their rated power for startup.
Do not exceed the current limit specified for any one receptacle. If an overloaded circuit causes the
AC circuit breaker or AC circuit protector to switch OFF, reduce the electrical load on the circuit, wait
a few minutes and then reset the AC circuit breaker or AC circuit protector.
AC Receptacle Selection
The generator has two separate main power producing circuits. These two circuits supply equal power
to different receptacles shown when the voltage selector switch is in the 120/240V position.
When two or more receptacles are used; prevent overloading by dividing the load between the two
power circuits.
The chart below shows the rated load in amperes that can be connected to each receptacle to balance
the generator.
The total rated ampere draw is 65A in 120V ONLY.
Main Power Circuit
Main Circuit 1
Main Circuit 2
The table shows the specifications when the 120/240V locking plug receptacle is used for 120V.
Receptacles Powered by
Each Main Circuit
2 and 5
1 and 4
Page 16 of 29
Power Distribution
2+5=32.5 A Rated
1+4=32.5 A Rated