1 Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to
start if a load is connected.
2 Turn the fuel valve lever to the ON position.
3 The choke will need to be closed, pull the choke rod out to the CLOSED position.
4 Turn the engine switch to the START position and hold it there for 5 seconds or until the
engine starts.
Operating the starter motor for more than 5 seconds can damage the motor. If the engine fails to start,
release the switch and wait 10 seconds before operating the starter again.
If the speed of the starter motor drops after a period of time, it is an indication that the battery should
be recharged.
When the engine starts, allow the engine switch to return to the ON position.
Push the choke to the OPEN position as the engine warms up.
Stopping the Engine
In an emergency:
To stop the engine in an emergency, move the engine switch to the OFF position.
In normal use:
1 Turn the AC circuit breaker to the OFF position. Disconnect DC battery charging cables.
2 Turn the engine switch to the OFF position.
3 Turn the fuel valve lever to the OFF position.
Page 13 of 29