How to discard a used battery Some FURUNO products have a battery(ies). To see if your product has a battery, see the chapter on Maintenance. Follow the instructions below if a battery is used. Tape the + and - terminals of battery before disposal to prevent fire, heat generation caused by short circuit.
Page 4
Turn off the power immediately if you Do not remove this label. If the label is missing feel the equipment is acting abnormally. or illegible, contact a FURUNO agent or dealer about replacement. If the equipment is hot to the touch or is...
Page 5
SAFETY INSTRUCTIONS Safety instructions for the installer WARNING CAUTION CAUTION The transducer cable must be handled Do not open the equipment. carefully, following the guidelines below. Only qualified personnel should work inside the equipment. • Keep fuels and oils away from the cable.
Thank you for considering and purchasing FURUNO. Features The DFF3 network sounder is a dual frequency echo sounder designed for use with the FURUNO NavNet, NavNet vx2, NavNet 3D and Navnet TZtouch series. The DFF3 feeds data about under- water conditions via a LAN.
MOUNTING Equipment Lists Standard supply Name Type Code No. Remarks Network Sounder DFF3 — Spare Parts SP02-05601 001-033-740 1 set Fuse Installation Materials CP02-08500 000-011-917 1 set - Power cable (3.5 m) - LAN cable (5 m) - Self-tapping screws...
Page 10
1. MOUNTING Transducer, thru-hull pipe and tank combinations Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 1k/1k 28/50 Steel 28F-8 TWB-6000(2) T-656 50B-9B 28/88 Steel 28F-8 TWB-6000(2) T-657 88B-8 50/88 Steel 50B-9B TWB-6000(2) T-658 88B-8 50/200 Steel 50/200-1T or TFB-5000(1) T-603 50/200-1ST...
1. MOUNTING • A magnetic compass will be affected if the network sounder is placed too close to it. Observe the compass safe distances noted in the safety instructions to prevent disturbance to the mag- netic compass. Fasten the network sounder to the mounting location with four self-tapping screws (5×20), refer- ring to the outline drawing at the back of this manual for mounting dimensions.
1. MOUNTING Optional Temperature Sensors 1.5.1 Transom mount temperature sensor T-02MTB • Fix the cable at a convenient location with cable clamp. • When the cable is led in through the transom board, make a hole of approx. 17 mm in diameter to pass the connector.
1. MOUNTING 1.5.2 Thru-hull temperature sensor T-02MSB, T-03MSB Select a suitable mounting location considering the following points: • Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular. However, the location should not be such that the transducer may be damaged when the boat is dry-docked.
MOD-WPAS0001-030+, 3 m TZT9/14 (for MFD8/12/BB /TZT9/14, standard supply) NavNet, MJ-A6SPF0017 NavNet vx2* (option: 1/5/10/20/30 m) HUB-101 MOD-Z072-050+, 5 m (option: 2/10 m) DFF3 H TRANSDUCER L NETWORK 12-24VDC TEMP 2.8-1.4A Temperature or Ground wire Speed/Temperature (IV-2 sq) Sensor White...
2. WIRING Transducer Cable TD-ID transducer (Airmar make transducer) The TD-ID type transducer can be connected to this equipment. However, note the following lim- itations: • TD-ID transducer cannot be used with NavNet, NavNet vx2. • TD-ID transducer cannot be used with non-TD-ID transducer. •...
Page 22
2. WIRING 4. Connect the transducer cable to the WAGO connector, following the instructions in the figure below and the interconnection diagram. (The opener for the WAGO connector is attached in- side the equipment. See the figure above.) Push Opener (attached inside the equipment) 1.
COMMON; connect the other end to A - E in the jumper block as applicable. For transducers not programmed, for example, Airmar make TD-ID transducer, consult a FURUNO agent or dealer for advice. Tap setting plug Tap setting plug (High freq.)
3. INITIAL SETTINGS DIP Switch Setting The DIP switch S2 sets up the system according to the equipment connected. In the default setting all switches (1-8) are OFF. The DIP switch S3 should not be adjusted; leave all switches in the OFF position.
Page 25
172.031.092.013 SOUNDER4 172.031.092.014 SOUNDER5 172.031.092.015 SOUNDER6 172.031.092.016 SOUNDER7 172.031.092.017 SOUNDER8 172.031.092.018 SOUNDER9 172.031.092.019 Transducer setting at NavNet series After setting up the transducer at the DFF3, set transducer type at NavNet 3D/TZtouch. See re- spective Installation Manual for the procedure.
For NavNet, NavNet vx2 and NavNet TZtouch, the DFF3 is powered on/off from ship’s switch- board. For NavNet 3D, it is powered on/off from the display unit. The LED on the cover of the DFF3 lights or blinks according to equipment state, as described in the table below.
MAINTENANCE NOTICE WARNING Do not apply paint, anti-corrosive ELECTRICAL SHOCK HAZARD Do not open the equipment. sealant or contact spray to coating or plastic parts of the equipment. Only qualified personnel should work inside the Those items contain organic solvents equipment.
#8: Restore all default settings. Use this when changing transducers. 4. Connect the power cable to the DFF3, and turn on the power at the ship’s switchboard. 5. The LED blinks (every four seconds) when default settings are completely restored.
Page 29
PACKING LIST 02GF-X-9851 -0 DFF3-J/E N A M E DESCRIPTION/CODE № O U T L I N E Q'TY ユニット UNIT ネットワーク魚探 DFF3 NETWORK SOUNDER 000-011-916-00 予備品 SPARE PARTS SP02-05601 ヒューズ FGB0-A 125V 5A PBF FUSE GLASS TUBE TYPE 000-155-853-10 工事材料...
Page 30
FURUNO DFF3 SPECIFICATIONS OF NETWORK SOUNDER DFF3 GENERAL TX frequency 28-200 kHz, two frequencies alternately transmitted (selectable) Output power 1/2/3 kW nominal Amplifier type Wide dynamic range linear amplifier (double superheterodyne) Depth range and Pulse repetition rate (PRR) 200 kHz, TX rate: 20 Range (m) PRR ( /min.)
Page 33
When a claim is made, FURUNO has a right to choose whether with other electronic devices. The imported product may also be to repair the product or replace it.
Page 34
24 months from installation date provided the work is done by Furuno U.S.A., Inc. or an AUTHORIZED Furuno dealer during normal shop hours and within a radius of 50 miles of the shop location.
Page 35
(title and/or number and date of issue of the standard(s) or other normative document(s)) For assessment, see • EMC Test Report FLI 12-08-007 of 18 February 2008 prepared by Furuno Labotech International Co., Ltd. This declaration is issued according to the Directive 2004/108/EC of the European Parliament and of...
Page 36
Nishinomiya, 662-8580, JAPAN A : MAR 2008 Printed in Japan All rights reserved. C : MAR . 01, 2012 Pub. No. OME-20370-C *00016858212* *00016858212* (DAMI ) DFF3 *00016858212* *00016858212* * 0 0 0 1 6 8 5 8 2 1 2 *...