Furuno DFF3 Operator's Manual
Hide thumbs Also See for DFF3:

Advertisement

Quick Links

OPERATOR'S MANUAL
NETWORK SOUNDER
DFF3
MODEL
www.furuno.com

Advertisement

Table of Contents
loading

Summary of Contents for Furuno DFF3

  • Page 1 OPERATOR'S MANUAL NETWORK SOUNDER DFF3 MODEL www.furuno.com...
  • Page 3: Important Notices

    How to discard a used battery Some FURUNO products have a battery(ies). To see if your product has a battery, see the chapter on Maintenance. Follow the instructions below if a battery is used. Tape the + and - terminals of battery before disposal to prevent fire, heat generation caused by short circuit.
  • Page 4 Turn off the power immediately if you Do not remove this label. If the label is missing feel the equipment is acting abnormally. or illegible, contact a FURUNO agent or dealer about replacement. If the equipment is hot to the touch or is...
  • Page 5 SAFETY INSTRUCTIONS Safety instructions for the installer WARNING CAUTION CAUTION The transducer cable must be handled Do not open the equipment. carefully, following the guidelines below. Only qualified personnel should work inside the equipment. • Keep fuels and oils away from the cable.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS FOREWORD ........................v SYSTEM CONFIGURATION ..................vi MOUNTING .......................1 1.1 Equipment Lists......................1 1.2 Network Sounder ......................8 1.3 Transducer ........................9 1.4 Optional Speed/Temperature Sensors ST-02MSB, ST-02PSB ........9 1.4.1 Mounting considerations..................9 1.4.2 Mounting procedure....................9 1.5 Optional Temperature Sensors ................... 10 1.5.1 Transom mount temperature sensor T-02MTB ...........
  • Page 7: Foreword

    Thank you for considering and purchasing FURUNO. Features The DFF3 network sounder is a dual frequency echo sounder designed for use with the FURUNO NavNet, NavNet vx2, NavNet 3D and Navnet TZtouch series. The DFF3 feeds data about under- water conditions via a LAN.
  • Page 8: System Configuration

    SYSTEM CONFIGURATION NavNet Series * HUB-100 (For NavNet/NavNet vx2) HUB* HUB-101 (For NavNet 3D/TZtouch) Network Sounder DFF3 DFF3 NETWORK SOUNDER ST-BY 12-24 VDC Rectifier PR-62 Speed/Temperature Sensor ST-02MSB ST-02PSB 100/110/115/ Temperature Sensor 220/230 VAC T-02MTB φ, 50/60 Hz T-02MSB T-03MSB High Freq.
  • Page 9: Mounting

    MOUNTING Equipment Lists Standard supply Name Type Code No. Remarks Network Sounder DFF3 — Spare Parts SP02-05601 001-033-740 1 set Fuse Installation Materials CP02-08500 000-011-917 1 set - Power cable (3.5 m) - LAN cable (5 m) - Self-tapping screws...
  • Page 10 1. MOUNTING Transducer, thru-hull pipe and tank combinations Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 1k/1k 28/50 Steel 28F-8 TWB-6000(2) T-656 50B-9B 28/88 Steel 28F-8 TWB-6000(2) T-657 88B-8 50/88 Steel 50B-9B TWB-6000(2) T-658 88B-8 50/200 Steel 50/200-1T or TFB-5000(1) T-603 50/200-1ST...
  • Page 11 1. MOUNTING Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 2k/2k 28/50 Steel 28F-18 TFB-7000(2) T-634 50B-12 TRB-1100(2) T-634-F 28/82 Steel 28F-18 TFB-7000(2) T-636 82B-35R TRB-1100(2) T-636-F 28/88 Steel 28F-18 TFB-7000(2) T-636 88B-10 TRB-1100(2) T-636-F 28/200 Steel 28F-18 TFB-7000(2) T-638 200B-8/8B TRB-1100(2)
  • Page 12 1. MOUNTING Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 2k/3k 28/150 Steel 28F-18 TFB-7000(2) T-637 150B-12H TRB-1100(2) T-637-F 50/107 Steel 50B-12 TFB-7000(2) T-643 100B-10R TRB-1100(2) T-643-F 50/150 Steel 50B-12 TFB-7000(2) T-644 150B-12H TRB-1100(2) T-644-F 3k/2k 68/200 Steel 68F-30H TFB-7000(2) T-647 200B-8/8B...
  • Page 13 1. MOUNTING Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 3k/3k 28/88 Steel 28BL-12HR TFB-7000(2) T-682 (con’t) 88F-126H TRB-1100(2) T-682-F Steel 28F-24H TFB-7000(2) T-682 88F-126H TRB-1100(2) T-682-F 28/150 Steel 28BL-12HR TFB-7000(2) T-683 150B-12H TRB-1100(2) T-683-F Steel 28F-24H TFB-7000(2) T-683 150B-12H TRB-1100(2) T-683-F...
  • Page 14 1. MOUNTING Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 3k/3k 50/200 Steel 50BL-24H TFB-7000(2) T-695 (con’t) 200B-12H TRB-1100(2) T-695-F Steel 50BL-24HR TFB-7000(2) T-683 200B-12H TRB-1100(2) T-683-F Steel 50F-24H TFB-7000(2) T-683 200B-12H TRB-1100(2) T-683-F 68/150 Steel 68F-30H TFB-7000(2) T-646 150B-12H TRB-1100(2) T-646-F...
  • Page 15 1. MOUNTING Output Frequency Thru-hull Ship type Transducer Tank (kHz) pipe 2k (con’t) Steel 50B-12 TFB-5000(1) T-611 TRB-1000(1) T-611-F Steel 50BL-12 TFB-5000(1) T-702 TRB-1000(1) T-702-F Steel 50BL-12HR TFB-5000(1) T-702 TRB-1000(1) T-702-F Steel 82B-35R TFB-5000(1) T-609 TRB-1000(1) T-609-F Steel 88B-10 TFB-5000(1) T-609 TRB-1000(1) T-609-F...
  • Page 16: Network Sounder

    1. MOUNTING Frequency Thru-hull Output (W) Ship type Transducer Tank (kHz) pipe Steel 28F-24H TFB-4000(1) T-616 TRB-1000(1) T-616-F Steel 28BL-12HR TFB-4000(1) T-616 TRB-1000(1) T-616-F Steel 38BL-15HR TRB-4000(1) T-616- TRB-1000(1) T-616-F Steel 50F-24H TFB-4000(1) T-616 TRB-1000(1) T-616-F Steel 50BL-24HR TFB-4000(1) T-616 TRB-1000(1) T-616-F Steel...
  • Page 17: Transducer

    1. MOUNTING • A magnetic compass will be affected if the network sounder is placed too close to it. Observe the compass safe distances noted in the safety instructions to prevent disturbance to the mag- netic compass. Fasten the network sounder to the mounting location with four self-tapping screws (5×20), refer- ring to the outline drawing at the back of this manual for mounting dimensions.
  • Page 18: Optional Temperature Sensors

    1. MOUNTING Optional Temperature Sensors 1.5.1 Transom mount temperature sensor T-02MTB • Fix the cable at a convenient location with cable clamp. • When the cable is led in through the transom board, make a hole of approx. 17 mm in diameter to pass the connector.
  • Page 19: Thru-Hull Temperature Sensor T-02Msb, T-03Msb

    1. MOUNTING 1.5.2 Thru-hull temperature sensor T-02MSB, T-03MSB Select a suitable mounting location considering the following points: • Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular. However, the location should not be such that the transducer may be damaged when the boat is dry-docked.
  • Page 20: Wiring

    MOD-WPAS0001-030+, 3 m TZT9/14 (for MFD8/12/BB /TZT9/14, standard supply) NavNet, MJ-A6SPF0017 NavNet vx2* (option: 1/5/10/20/30 m) HUB-101 MOD-Z072-050+, 5 m (option: 2/10 m) DFF3 H TRANSDUCER L NETWORK 12-24VDC TEMP 2.8-1.4A Temperature or Ground wire Speed/Temperature (IV-2 sq) Sensor White...
  • Page 21: Transducer Cable

    2. WIRING Transducer Cable TD-ID transducer (Airmar make transducer) The TD-ID type transducer can be connected to this equipment. However, note the following lim- itations: • TD-ID transducer cannot be used with NavNet, NavNet vx2. • TD-ID transducer cannot be used with non-TD-ID transducer. •...
  • Page 22 2. WIRING 4. Connect the transducer cable to the WAGO connector, following the instructions in the figure below and the interconnection diagram. (The opener for the WAGO connector is attached in- side the equipment. See the figure above.) Push Opener (attached inside the equipment) 1.
  • Page 23: Initial Settings

    COMMON; connect the other end to A - E in the jumper block as applicable. For transducers not programmed, for example, Airmar make TD-ID transducer, consult a FURUNO agent or dealer for advice. Tap setting plug Tap setting plug (High freq.)
  • Page 24: Dip Switch Setting

    3. INITIAL SETTINGS DIP Switch Setting The DIP switch S2 sets up the system according to the equipment connected. In the default setting all switches (1-8) are OFF. The DIP switch S3 should not be adjusted; leave all switches in the OFF position.
  • Page 25 172.031.092.013 SOUNDER4 172.031.092.014 SOUNDER5 172.031.092.015 SOUNDER6 172.031.092.016 SOUNDER7 172.031.092.017 SOUNDER8 172.031.092.018 SOUNDER9 172.031.092.019 Transducer setting at NavNet series After setting up the transducer at the DFF3, set transducer type at NavNet 3D/TZtouch. See re- spective Installation Manual for the procedure.
  • Page 26: Operation Check

    For NavNet, NavNet vx2 and NavNet TZtouch, the DFF3 is powered on/off from ship’s switch- board. For NavNet 3D, it is powered on/off from the display unit. The LED on the cover of the DFF3 lights or blinks according to equipment state, as described in the table below.
  • Page 27: Maintenance

    MAINTENANCE NOTICE WARNING Do not apply paint, anti-corrosive ELECTRICAL SHOCK HAZARD Do not open the equipment. sealant or contact spray to coating or plastic parts of the equipment. Only qualified personnel should work inside the Those items contain organic solvents equipment.
  • Page 28: Replacing The Fuse

    #8: Restore all default settings. Use this when changing transducers. 4. Connect the power cable to the DFF3, and turn on the power at the ship’s switchboard. 5. The LED blinks (every four seconds) when default settings are completely restored.
  • Page 29 PACKING LIST 02GF-X-9851 -0 DFF3-J/E N A M E DESCRIPTION/CODE № O U T L I N E Q'TY ユニット UNIT ネットワーク魚探 DFF3 NETWORK SOUNDER 000-011-916-00 予備品 SPARE PARTS SP02-05601 ヒューズ FGB0-A 125V 5A PBF FUSE GLASS TUBE TYPE 000-155-853-10 工事材料...
  • Page 30 FURUNO DFF3 SPECIFICATIONS OF NETWORK SOUNDER DFF3 GENERAL TX frequency 28-200 kHz, two frequencies alternately transmitted (selectable) Output power 1/2/3 kW nominal Amplifier type Wide dynamic range linear amplifier (double superheterodyne) Depth range and Pulse repetition rate (PRR) 200 kHz, TX rate: 20 Range (m) PRR ( /min.)
  • Page 31 28/Mar/08 R.Esumi...
  • Page 33 When a claim is made, FURUNO has a right to choose whether with other electronic devices. The imported product may also be to repair the product or replace it.
  • Page 34 24 months from installation date provided the work is done by Furuno U.S.A., Inc. or an AUTHORIZED Furuno dealer during normal shop hours and within a radius of 50 miles of the shop location.
  • Page 35 (title and/or number and date of issue of the standard(s) or other normative document(s)) For assessment, see • EMC Test Report FLI 12-08-007 of 18 February 2008 prepared by Furuno Labotech International Co., Ltd. This declaration is issued according to the Directive 2004/108/EC of the European Parliament and of...
  • Page 36 Nishinomiya, 662-8580, JAPAN A : MAR 2008 Printed in Japan All rights reserved. C : MAR . 01, 2012 Pub. No. OME-20370-C *00016858212* *00016858212* (DAMI ) DFF3 *00016858212* *00016858212* * 0 0 0 1 6 8 5 8 2 1 2 *...

Table of Contents