Astria Fireplaces ParisLights43ZEN Installation & Operation Instructions

Unvented vent-free gas fireplace

Advertisement

P/N 126875-01 Rev. G 12/2016
P126875-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where
not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on page 5 of this manual.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Unvented (Vent-Free) Gas Fireplace
PFS
Models
®
US
REPORT NO. F11-054
ParisLights43ZEN
ParisLights43ZEP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ParisLights43ZEN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces ParisLights43ZEN

  • Page 1 Installation and Operation Instructions Unvented (Vent-Free) Gas Fireplace Models P/N 126875-01 Rev. G 12/2016 ® ParisLights43ZEN ParisLights43ZEP REPORT NO. F11-054 P126875-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety .....................2 Please carefully read and follow all instructions in this manual. Pay Local Codes ...................3 special attention to all warnings and safety information. Requirements for the Commonwealth of Massachusetts....4 Product Identification ..............4 Following these safety, care, and operation instructions will help Product Features ................5...
  • Page 3: Local Codes

    SAFETY Continued and Maintenance, page 20. WARNING: Do not use a blower insert, heat ex- 9. Before using furniture polish, wax, carpet cleaner, or similar changer insert or other accessory not approved for products, turn heater off. If heated, the vapors from these prod- use with this heater.
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    LOCAL CODES Continued COMMONWEALTH OF MASSACHUSETTS REQUIRE- MENTS State of Massachusetts: The installation must be made by a These appliances are approved for installation in the US state of Mas- licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts if the following additional requirements are met: sachusetts.
  • Page 5: Product Features

    PRODUCT FEATURES OPERATION SAFETY DEVICE This vent-free fireplace is clean burning. It requires no outside This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) venting. There is no heat loss out a vent or up a chimney. Heat is safety shutoff system.
  • Page 6 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION WARNING: If the area in which the heater may be Determining if You Have a Confined or Unconfined Space operated does not meet the required volume for indoor Use this work sheet to determine if you have a confined or uncon- combustion air, combustion and ventilation air shall fined space.
  • Page 7: Installation

    INSTALLATION INSTALLATION CLEARANCES NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary WARNING: Maintain the minimum clearances. If heating system. Do not install this heater as your you can, provide greater clearances from floor, ceiling primary heat source.
  • Page 8 INSTALLATION Continued FOR ONE SIDED APPLICATION, STUDS " MOUNTED INSIDE OF ARE NOT MOUNTED NAILING FLANGE (FLAT) TO THE REAR Concrete OF NAILING FLANGES Board 38" " Figure 6 - Installing Concrete Board Mantel Mantel from Top Note: All vertical Ref.
  • Page 9 INSTALLATION Continued " " " " " " " " " 1" " 47" 52" " Gas Line Gas Line Access Access Electrical Outlet " 1" " Figure 8 - ParisLights43 Series Dimensions 126875-01_G Astria.US.com...
  • Page 10 INSTALLATION Continued Mantel Clearances for Built-In Installation CHECK GAS TYPE If placing mantel above built-in fireplace, you must meet minimum Use proper gas type for the fireplace unit you are installing. If you clearance between mantel shelf and top of fireplace opening. have conflicting gas types, do not install fireplace.
  • Page 11 INSTALLATION Continued External Equipment Shutoff Valve Propane/LP Regulator With 1/8" NPT Tap* Supply Tank Natural Gas From Gas Meter (5" W.C.** to 10.5" W.C. Pressure) Vent Propane/LP Pointing From External Down Regulator (11" W.C.** to 14" W.C. Pressure) 3" Minimum Figure 10 - External Regulator on Propane/LP Supply Tank with Vent Pointing Down Pipe...
  • Page 12 INSTALLATION Continued CHECKING GAS CONNECTIONS Open Equipment Shutoff Valve WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. Closed WARNING: Never use an open flame to check for a leak.
  • Page 13 INSTALLATION Continued UPGRADING PARISLIGHTS43 TO SEE-THRU APPLICATION FINISHING FIREPLACE FOR INSTALLATION Removing Rear Panel ParisLights43 series fireplace come with the rear panel semi-installed. If you will be using the fireplace for a one sided regular application, 1. In the rear of the fireplace, locate screws at top of rear panel and you will need to finish the installation of the rear panel.
  • Page 14 INSTALLATION Continued Removing False Door 1. In the rear of the fireplace, Unlock 3 door latches on top of firebox using your fingers or the latch opener provided. 2. Hook opener over latch as shown in Figure 20. Swing the bot- tom of the opener down toward the door.
  • Page 15: Gas Control Module System

    INSTALLATION Continued GLASS PEBBLE INSTALLATION REPLACING LIGHT BULBS 1. Unplug power WARNING: Do not change or substitute glass 2. Remove access door (see Figure 24, page 14). pebbles provided with this fireplace. If replacing, use 3. Remove glass panel if installed (see Figure 25a). 4.
  • Page 16: Remote Control Operation

    GAS CONTROL MODULE SYSTEM Continued NOTE: The module must be programmed to the Remote Control NOTE: Make sure the valve module and light module are plugged transmitter. into the electric duct assembly. • To program the module (make sure the system has power), BATTERY BACK-UP locate the learn button on left side as shown in Figure 27, page 15.
  • Page 17 REMOTE CONTROL OPERATION Continued MODE Zone: Blank • Temperatures may be displayed in degrees F (factory default) or degrees C. Press the UP and DOWN Buttons simultaneously to ROOM TEMP Zone: Blank change between degrees F and C. SET TEMP Zone: Blank •...
  • Page 18 LIGHT Zone: LIGHT and light setting level is displayed LIGHT ADJUSTMENT FAN Zone: FAN and fan setting level is displayed • Transmits a light setting command to the control module to adjust the light output level. TIME/PROG Zone: Current day indicator and current time is •...
  • Page 19: Operating Fireplace

    OPERATING FIREPLACE 6. Wait five (5) minutes to clear out any gas. Then smell for gas, FOR YOUR SAFETY including near the floor. If you smell gas, STOP! Follow “B” in READ BEFORE LIGHTING the safety information. If you don't smell gas, go to the next step. 7.
  • Page 20: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Ports/Slots Burner WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burner and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person.
  • Page 21: Inspecting Burners

    • turn fireplace off (see To Turn Off Gas to Appliance, page 19) from pilots shown) • see Troubleshooting, page 23 Thermocouple Pilot Burner SPECIFICATIONS ParisLights43ZEN • Rating (Variable): 25/39,000 Btu/Hr • Gas Type: Natural Gas • Ignition: Piezo • Pressure Manifold Setting: 3.5" W.C. • Inlet Gas Pressure (in. of water): Maximum - 10.5"...
  • Page 22: Wiring Diagram

    WIRING DIAGRAM LEARN MOTOR COMM Blk. Brown Yellow Orange Astria.US.com 126875-01_G...
  • Page 23: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 24 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Slight smoke or odor during initial operation 1. Not enough air 1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Mainte- nance, page 20) Heater produces a whistling noise when 1.
  • Page 25 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately •...
  • Page 26: Parts

    PARTS MODELS PARISLIGHTS43ZEN & PARISLIGHTS43ZEP Astria.US.com 126875-01_G...
  • Page 27 30 of this manual. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. ParisLights43ZEN ParisLights43ZEP NO. CATALOG NO. DESCRIPTION...
  • Page 28 PARTS MODELS PARISLIGHTS43ZEN & PARISLIGHTS43ZEP Astria.US.com 126875-01_G...
  • Page 29 30 of this manual. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. ParisLights43ZEN ParisLights43ZEP NO. CATALOG NO. DESCRIPTION...
  • Page 30: Replacement Parts

    TECHNICAL SERVICE ACCESSORIES Purchase these accessories thru your IHP distributor or dealer. You may have further questions about installation, operation, or troubleshooting. Please contact your IHP dealer for any questions or concerns a. When contacting your dealer please have your model and serial numbers of your fireplace ready.
  • Page 31: Warranty

    Innovative Hearth Products Astria Brand Gas Fireplace ® Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria brand gas fi replace ("Product") to be free from defects in materials and workmanship ® at the time of manufacture. The product body, fi rebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 32 Astria.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name P126875-01 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

This manual is also suitable for:

Parislights43zepF1219F1220

Table of Contents